3
FRRA Series
Instruction Manual
Optical Receiver
Bandwidth: 47 to 860 MHz
Bandpass Flatness: 2.0 dB P/V
Operating Wavelength: 1310/1550 nm
Optical Input Range: -6.0 to +3.0 dBm
Output Impedance: 75 ohm
CNR -1 dBm Input, 40 Ch. Load: 57 dB
CNR -1 dBm Input, 79 Ch.+ Data: 55 dB
CNR -1 dBm Input, 110 Ch. Load: 54 dB
Input Connector: FRRA-S4A-xx: FC/APC
FRRA-S4S-xx: SC/APC
Distribution Amplifier
Impedance - All Ports: 75 ohm
Return Loss Output: 16 dB
RF Gain: 43 dB
Test Port: -20, ±2 dB
Gain Control Range: 10 dB
Slope Control Range: 8 dB
Operating Temperature: -20 to +45˚C
Power Supply Requirements 117 VAC, 60 Hz: 28 W
Size (W x H x L): 19 x 1.75 x 6.25 in., 48.26 x 4.45 x 15.88 cm
Weight: 5.75 lbs., 2.61 kg
Number Of Hybrids: 2
Hybrid Technology: Power Doubling
Varying Specifications
Channel Loading:
110
Flatness:
± 0.5
Output Level (Low/High)
34/42
Composite Triple Beat (CTB)
(a,b,c)
:
-60
Composite Second Order (CSO)
(a,b,c)
: -58
Hum Modulation:
-70
The FRRA is a fiber optic receiver integrated with the Blonder Tongue RMDA rack mount distribution amplifier.
The FRRA may be used as a launch amplifier in a coaxial distribution network after networking with fiber. The fiber
receiver provides a robust system for transferring 110 channels (depending on model) VSB/AM modulated signals
over a single mode fiber. The FRRA operates with the FIBT Series of transmitters as well as with the transmitters of
many other leading manufacturers. The FRRA-S4A-860-43-PA can transfer 79 channels of VSB/AM signals, plus 57
digital QAM channels in the upper frequency range.
Description
Specifications-LINK(d) @ 25°C, Single-mode Fiber (Typical)
NOTES:
(a) At specified channel loading at rated output capability
(b) Distortion levels improve as output level is reduced
(c) Distortion specifications at 8 dB sloped output
(d) Assumes FIBT transmitter link and -1 dBm optical input
48
50
52
54
56
58
60
62
64
-10
-8
-6
-4
-2
0
+2
+4
Optical Input Level
CNR
110 Ch.
79 Ch. & data
40 Ch.
24 Ch.
10 Ch.
5 Ch.