![Blomberg GSN 1580 Manual Download Page 12](http://html1.mh-extra.com/html/blomberg/gsn-1580/gsn-1580_manual_2773929012.webp)
35
36
Water drainage
Connecting the drainage hose.
Take care to ensure that the drainage hose is not bent
or squeezed.
Check that the drainage hose is firmly seated.
Extension hoses
If a hose extension is required, a drainage hose of equal
quality must be used.
The maximum length must not exceed 4m. Using a longer
hose will produce poorer cleaning results
Siphon connection
The drainage height must be between 50 and 100 cm
above the floor.
Use hose clamps to fasten the drainage hose to the
siphon.
Electrical connection
Please refer to the type plate for information on current
type, mains voltage, and fuse protection.
The type plate is located on the inside of the door.
The mains plug must be freely accessible after installation.
Power cables and insulated cables must not be accessible
(exposed) after installation.
Installing Your Dishwasher
Choose a suitable location for your dishwasher. Take
care to ensure that the appliance is stable on a level
surface.
Unevenness in the floor can be equalised by adjusting
the screw feet. When the appliance is standing correctly,
the door can be closed without difficulty.
Water inlet and drainage hoses must be positioned so
that they can move freely without bending or squeezing.
The appliance may not be installed in a room where
the temperature is below 0° Celsius.
Water connection
The dishwasher may be connected to cold and warm
water to a maximum temperature of 60° Celsius.
The dishwasher may not be connected to open warm
water devices or flow-through water heaters.
Connect water inlet hose
Ensure that the water inlet hose is not bent or squeezed.
Do not install a used hose set.
Use a screw-on hose connector to connect the water
inlet hose to a water tap with a ¾ inch external thread.
If required, use a filter insert to filter deposits from the
pipes.
Check that the connection does not leak.
Important
For safety reasons, turn off the tap after every rinse
process.
Lowest permitted
water pressure:
0.3 bars = 3 N/cm² = 30 kPa
When the water pressure is
below1 bar, please contact your
technician.
Permitted water pressure:
When the water pressure is above
10 bars, a pressure reduction valve
must be installed (available in trade
supply stores).
Highest permitted
water pressure:
10 bar = 100N/cm² = 1MPa
A (some models)
The A System protects against water damage
which may be caused at the water inlet hose.
Do not immerse the systems valve box into water; it
contains electrical components.
In case of damage, pull out the power supply plug.
Do not shorten or lengthen the hose insert as it contains
electrical cables and components.
3/4
min 10
3/4
3/4 1/2
CH
DK
S
N
SF
3/4
min 10
A
18
21
01
0
20
30
40
50
60
70
80
90
100
11
0
12cm
min 4cm
max 110 cm
min 50 cm
All manuals and user guides at all-guides.com