2.0 SERVICE CONNECTIONS
NOTE: PRESSURE REDUCING VALVE -OPTIONAL
DIMENSIONS ARE IN INCHES [MM]
S
Field Wiring Electrical Connection to be as specified on data plate.
STEAM TAKE-OFF CONNECTION: 3/4"IPS to operate adjacent equipment.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
DRAIN: 2"IPS piped to open floor drain. No Solid Connection.
HOT WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
inches
UNITS
mm
540
21.25
5.75
146
222
A
8.75
DIMENSIONS
16.75
425
B
C
D
584
23
E
F
89
3.5
G
267
10.5
H
64
2.5
J
283
11.12
K
121
4.75
2.5
L
64
M
P
222
8.75
18
457
WIDTH
36
914
24
610
inches
mm
70
2.75
330
13
502
19.75
N
4.75
121
171
6.75
ELECTRICAL CHARACTERISTICS
99.9
115.4
116.6
3
3
1
PHASE
208V
110.2
101.0
220V
109.1
94.5
240V
AMPS PER LINE
100.0
86.6
480V
58.4
63.8
415V
54.7
N/A
380V
N/A
50.1
50.5
N/A
43.3
69
128
107
OUTPUT
MAX. LBS/HR.
24
42
36
kW
3
148
48
N/A
N/A
115.5
72.9
66.8
57.7
3
69
66.6
62.9
57.7
36.5
33.4
28.9
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids
Total alkalinity
Silica
Chlorine
pH Factor
Water which fails to meet these standards should be treated by installation of a water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Less than 60 PPM
Less than 20 PPM
Less than 13 PPM
Less than 1.5 PPM
7.0-8.5