17
CAUTION: If burner does not shut off during blowdown,
immediately discontinue use of appliance and call for service.
Continue draining water for about fifteen (15) seconds, from control until water is clean.
Manually close valve. Recheck gauge glass. If water level has dropped significantly,
wait for the boiler to restore water level and pressure and repeat if necessary.
WARNING: Disconnect the power supply to the appliance before
cleaning or servicing.
1. If water in sight glass is not clear and appears murky, this indicates poor water quality
and may cause control failure. SEE WATER QUALITY STATEMENT, page 4.
2. Safety valve should be tripped during operation once a week to ensure that it is
functioning properly.
3. Clean around burners and orifices if lint has accumulated.
4. Visually ensure carry over ports are unobstructed.
5. Visually check that the flue is not obstructed.
CLEANING
DO NOT allow water near the electrical components.
At the end of the day, turn the Main Power Switch OFF (automatic blowdown drains the
boiler tank) or if equipped with manual blowdown valve, open it. Wash exterior with mild
detergent and warm water, rinse, and wipe dry. Do not use steel wool on stainless steel
surfaces.
REMOVAL OF LIME SCALE DEPOSITS
The interior of the steam boiler should be inspected at least twice a year by your
authorized servicer to determine whether the boiler needs to be delimed. The servicer
should perform any necessary deliming procedure. See descaling instructions.