Blizzard ToughPAR Quadra LED User Manual Download Page 9

Page 9

ToughPAR Quadra Manual Rev. A    

 

Copyright (c) 2012 Blizzard Lighting, LLC

Fixture Linking (Master/Slave Mode)

1.  Connect the (male) 3 pin connector side of the 

DMX cable to the output (female) 3 pin connector of 

the fi rst fi xture.

2.  Connect the end of the cable coming from the 

fi rst fi xture which will have a (female) 3 pin connec-

tor to the input connector of the next fi xture con-

sisting of a (male) 3 pin connector. Then, proceed 

to connect from the output as stated above to the 

input of the following fi xture and so on.

A quick note:  Often, 

the setup for Master-

Slave and Standalone 

operation requires that 

the fi rst fi xture in the 

chain be initialized for 

this purpose via either 

settings in the control 

panel or DIP-switches. 

Secondarily, the fi xtures 

that follow may also re-

quire a slave setting. 

Check the “Operating Adjustments” section in this manual for com-

plete instructions for this type of setup and confi guration.

Mounting & Rigging
This fi xture may be mounted in any SAFE position provided there is 

enough room for ventilation.

It is important never to obstruct the fan or vents pathway. Mount the 

fi xture using a suitable “C” or “O” type clamp.  The clamp should be 

rated to hold at least 10x the fi xture’s weight to ensure structural sta-

bility.  Do not mount to surfaces with unknown strength, and ensure 

properly “rated” rigging is used when mounting fi xutres overhead.

Adjust the angle of the fi xture by loosening both knobs and tilting the 

fi xture. After fi nding the desired position, retighten both knobs.

•  When selecting installation location, take into consideration lamp 

replacement access (if applicable) and routine maintenance.
•  Safety cables MUST ALWAYS be used.
•  Never mount in places where the fi xture will be exposed to rain, 

high humidity, extreme temperature changes or restricted ventilation.

Summary of Contents for ToughPAR Quadra LED

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Brookfield WI USA Copyright c 2012...

Page 2: ...acement 7 Connecting A Bunch Of ToughPAR Quadra PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9...

Page 3: ...le resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixt...

Page 4: ...fore servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT oper...

Page 5: ...As Nails IP65 rated enclosure Light source 18x 10 watt 4 in 1 LEDs Totally silent convection cooling Dual mounting brackets for positioning flexibility Flicker free constant current LED driver DMX Qui...

Page 6: ...izzard Lighting LLC Figure 1 The ToughPAR Pin Up Picture High Power 4 in 1 LEDs IP65 Rated Cast Aluminum Enclosure Mounting Yoke Adjustment Locking Knobs Figure 2 The Rear Connections DMX Power In LED...

Page 7: ...t Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result...

Page 8: ...ou d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Use...

Page 9: ...eck the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided ther...

Page 10: ...OWN Scrolls through menu items and numbers in descending order SAVE Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the men...

Page 11: ...NTER So A ENTER LED ENTER ON OFF UP DOWN ENTER SP ENTER SP00 SP15 UP DOWN ENTER Pr ENTER Pr00 Pr30 UP DOWN ENTER ASC ENTER AC00 AC15 UP DOWN ENTER FAdE ENTER FA00 FA15 UP DOWN ENTER FLAS ENTER r000 r2...

Page 12: ...ress the EN TER button to confirm 4 Adjust the speed of the chase as above using SP15 slowest to SP00 fastest then press the ENTER button to confirm 5 To set the fixture as a slave unit select SLAV an...

Page 13: ...9 000 005 006 055 056 105 106 155 156 205 206 255 32 Bit Dimmer As set in the control menu display Mode 0 8 bit 256 dimming steps Mode 1 32 bit 0 25 intensity range Mode 2 32 bit 0 50 intensity range...

Page 14: ...ct position if applicable Also check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Fixture Not R...

Page 15: ...ical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of...

Page 16: ...satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sendin...

Page 17: ...Ds 100 000 hours Optical Beam Angle 25 degree optics standard 26 degree beam 30 degree field Luminous Intensity 25 000 Lux 1m 25 degree optics Thermal Max Operating Temp 104 degrees F 40 degrees C amb...

Page 18: ...Page 18 ToughPAR Quadra Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Page 19: ...This page intentionally left blank...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...