Cable Connectors

Cables must have a male XLR connector on one end and a female XLR connec-

tor on the other end. (Duh!)

CAUTION:

 Do not allow contact between the common and the 

fixture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with only a 3-pin DMX output connector, you will need to use a 3-pin to 5-pin 

adapter. They are widely available over the internet and from specialty retailers.  If you’d like to build your 

own, the chart below details a proper cable conversion:

Conductor

3-pin Male (Input)

5-Pin Female (Output)

Ground/Shield

Pin 1

Pin 1

Data 1- (Primary Data Link)

Pin 2

Pin 2

Data 1+ (Primary Data Link)

Pin 3

Pin 3

Data 2- (Optional Secondary Data Link)

n/c

Pin 4

Data 2+ (Optional Secondary Data Link)

n/c

Pin 5

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the DMX cable to the female connector (output) on 

the controller.

Step 2:

 Connect the female connector of the 

DMX cable to the first fixture’s male connector 

(input).  

Note:

  It doesn’t matter which 

fixture address is the first one connected.  We 

recommend connecting the fixtures in terms 

of their proximity to the controller, rather than 

connecting the lowest fixture number first, and 

so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture to 

ensure best communication.

Summary of Contents for Mister Stroboto

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Page 2: ...Mister Stroboto Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Mister Stroboto Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Fixture Linking Master Slave Mode...

Page 3: ...ocal power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions...

Page 4: ...ation slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER...

Page 5: ...isplay with 4 button control Operating modes DMX512 Master Slave Auto DMX Quick Reference 2 4 12 29 45 Channel Modes 2CH 4CH 12CH 29CH 45CH What It Does 1 1 1 1 Dimmer 0 100 1 2 2 2 2 Strobe 3 3 3 Fla...

Page 6: ...oboto Pin Up Picture Figure 2 The Rear Connections Figure 1 Mister Stroboto Pin Up Picture 4 Button Control Panel with 2 4 TFT Color Display 32 3 watt 3 in 1 RGB LEDs 8 100 watt 6500K CTO White LEDs C...

Page 7: ...ata link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recomm...

Page 8: ...the chart below details a proper cable conversion Conductor 3 pin Male Input 5 Pin Female Output Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Da...

Page 9: ...he fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging Thi...

Page 10: ...odic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution...

Page 11: ...able rigging point together When mounting this fixture to truss be sure to secure an appropriately rated clamp to the omega bracket using an M10 screw fitted through the center hole of the omega brack...

Page 12: ...the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows the menu items you se...

Page 13: ...See pages 14 15 Strobe 000 255 Strobe Program 000 255 Program Speed 000 255 Background Dimmer 000 255 Background Strobe 000 255 Color Macro 000 255 Macro Auto 000 255 Macro Speed 000 255 Settings Dis...

Page 14: ...LED Dimmer 1 0 100 5 5 000 255 White LED Dimmer 2 0 100 6 6 000 255 White LED Dimmer 3 0 100 7 7 000 255 White LED Dimmer 4 0 100 8 000 255 White LED Dimmer 5 0 100 9 000 255 White LED Dimmer 6 0 100...

Page 15: ...9 Program 10 131 142 143 154 155 166 167 178 179 190 191 202 203 214 215 226 227 238 239 255 Program 11 Program 12 Program 13 Program 14 Program 15 Program 16 Program 17 Program 18 Program 19 Program...

Page 16: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the...

Page 17: ...d wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for s...

Page 18: ...F 40 degrees C ambient Control Protocol USITT DMX 512 Art Net RDM DMX Channels 2 4 12 29 45 Input 5 pin XLR Male Output 5 pin XLR Female Other Operating Modes DMX512 Master Slave Auto Warranty 2 year...

Page 19: ...Page 19 Mister Stroboto Manual Rev A c 2019 Blizzard Lighting LLC Dimensional Drawings 11 3 287 mm 3 9 287 mm 4 6 116 6 mm 8 9 225 8 mm 17 4 439 8 mm 19 481 5 mm 20 1 508 5 mm...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: