Blizzard Lighting The Puck RGB Unplugged Manual Download Page 4

Page 4

             The Puck: Unplugged RGB Manual Rev. A 

 

Copyright (c) 2011 Blizzard Lighting, LLC

1. GETTING STARTED

What’s In The Box?

 

• 1 x Puck: UNPLUGGED™ RGB Flat LED PAR Fixture

 

• 1x IEC Power Cord

 

• This Lovely User Manual

Getting It Out Of The Box

Congratulations on purchasing one way cool, way THIN LED PAR fi x-

ture!  Now that you’ve got The Puck: UNPLUGGED™ RGB (or hopefully, 

Pucks!), you should carefully unpack the box and check the contents 

to ensure that all parts are present and in good condition. If anything 

looks as if it has been damaged in transit, notify the shipper immedi-

ately and keep the packing material for inspection.  Again, please save 

the carton and all packing materials. If a fi xture must be returned to 

the factory, it is important that the fi xture be returned in the original 
factory box and packing.

Powering Up!

All fi xtures must be powered directly off a switched circuit and cannot 

be run off a rheostat (variable resistor) or dimmer circuit, even 

if the rheostat or dimmer channel is used solely for a 0% to 

100% switch.  

AC Voltage Switch - Not all fi xtures have a voltage select switch, so 

please verify that the fi xture you receive is suitable for your local pow-

er supply.  See the label on the fi xture or refer to the fi xture’s specifi -

cations chart for more information.  A fi xture’s listed current rating is 

its average current draw under normal conditions. Check the fi xture or 

device carefully to make sure that if a voltage selection switch exists 

that it is set to the correct line voltage you will use.

Warning! Verify that the voltage select switch on your unit 

matches the line voltage applied. Damage to your fi xture may 

result if the line voltage applied does not match the voltage 

indicated on the voltage selector switch. All fi xtures must be 
connected to circuits with a suitable Ground (Earthing).

Getting A Hold Of Us

If something is wrong, just give us a call or send an email.  

We’ll be happy to help, honest.
Blizzard Lighting

W220 N1531 Jericho Ct. Suite E., Waukesha, WI 53186 USA

[email protected]

www.blizzardlighting.com

866.493.6025

Summary of Contents for The Puck RGB Unplugged

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright c 2011 ...

Page 2: ...GB LED PAR Can 6 Features 6 DMX Quick Reference 4 and 7 Channel Modes 6 The Puck UNPLUGGED RGB Pin up Picture 7 3 Setup 8 Fuse Replacement 8 Connecting A Bunch Of Puck UNPLUGGED RGBs 8 Data DMX Cables 8 Using this fixture with the wiCICLE Wireless DMX System 9 4 Operating Adjustments 10 Using the Battery System DMX Mode DMX Mode Selection 10 Master Slave Mode 11 Sound Active Mode 11 Custom Color D...

Page 3: ...of the bat tery pack 5 DO NOT BURN OR INCINERATE BATTERY PACKS Battery packs may explode causing personal injury fire and or damage Fumes resulting from burning of battery packs may be toxic 6 DO NOT DROP CRUSH IMPACT OR MECHANICALLY ABUSE BATTERY PACKS Cease use of fixtures that have suffered a sharp impact been dropped run over or damaged in any other way Such impacts may cause internal damage t...

Page 4: ...or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local pow er supply See the label on the fixture or refer to the fixture s specifi cations chart for more information A fixture s listed current rating is its average current ...

Page 5: ...e before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unski...

Page 6: ...ADDITIONAL FEATURES Lightweight and Compact It kept its New Years resolution High output long running Lithium Ion rechargable battery system 4 Button LED control panel for easy programming Light source 144x 10mm LEDs 36 each Red Green Blue Dual bracket for flexibility in mounting Power outlet for fixture linking up to 50 fixtures AC power only DMX Quick Reference 6 Channel Mode Channel What It Doe...

Page 7: ...l Rev A Copyright c 2011 Blizzard Lighting LLC Figure 1 The Puck UNPLUGGED RGB Pin Up Picture High Power LEDs Ridiculously thin Dual Mounting Yokes Figure 2 The Rear Connections AC Power In Out DMX In DMX Out LED Control Panel Microphone ...

Page 8: ...ecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade ca...

Page 9: ...re is set to slave mode simply plug the wiCICLE receiver into the DMX IN connector on the back of the fixture The fixture will automatically detect and power the wiCICLE Follow the instructions provided on the wiCICLE instruction sheet to select change frequency groups GROUP 1 RED GROUP 2 GREEN GROUP 3 YELLOW GROUP 4 BLUE GROUP 5 VIOLET GROUP 6 CYAN GROUP 7 WHITE Check it out the group number corr...

Page 10: ...he Fixture From The Battery 1 Switch the top switch to position I BAT ON 2 Switch the bottom switch to position O OFF To Operate The Fixture From AC Power 1 Switch the top switch to position O BAT OFF 2 Switch the bottom switch to position ON To Operate The Fixture From AC Power Charge The Battery 1 Switch the top switch to position II CHARGE 2 Switch the bottom switch to position ON To Charge The...

Page 11: ...y using the UP DOWN keys to reach SLAV in the Master Auto menu on the slave units and they will react in the same as the Master Slave SLNd then SLAu to confirm 4 On the master fixture use the UP DOWN keys to reach SHND which allows you to select the Master Slave mode Sound active SoUn then ENTER to confirm Auto mode CoLo then Auto then ENTER to confirm Color preset CoLo then CoL 1 CoL 15 ENTER To ...

Page 12: ...lown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropri ately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Fixture Not Respo...

Page 13: ... your cli ent s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn...

Page 14: ...gle 21 degrees 32 degree field Luminous Intensity 3 920 Lux 1m Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 3 or 6 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Standalone color mixing Battery Type Rating Field replacable Lithium Ion 11 1V 8 0Ah with b...

Page 15: ...Page 15 The Puck Unplugged RGB Manual Rev A Copyright c 2011 Blizzard Lighting LLC Thine pagest hath beenst lefteth blanketh on purposeth ...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Reviews: