Blizzard Lighting Puck QFX User Manual Download Page 8

Page 8

The Puck™ QFX Manual Rev. A 

 

 

Copyright (c) 2012 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

With a flat head screwdriver, wedge the fuse holder out of its 

housing. Remove the damaged fuse from its holder and replace 

with exact same type fuse. Insert the fuse holder back in its 

place and reconnect power.

Connecting A Bunch of Puck™ QFX Flat LED PAR Cans

You will need a serial data link to run light shows using a DMX-

512 controller or to run shows on two or more fixtures set to 

sync in master/slave operating mode. The combined number of 

channels required by all the fixtures on a serial data link determines the number of fixtures the data link 

can support.

Fixtures on a serial data link must be daisy chained in one single line. Also, connecting more than 32 fix

-

tures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal.

The maximum recommended cable-run distance is 500 meters (1640 ft).  The maximum recommended 

number of fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-grade cables that can carry a high 

quality signal and are less prone to electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 applications. Standard microphone 

cables will “probably” be OK, but note that they cannot transmit DMX data as reliably over long distances.  

In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

USInG THIS FIXTURE WITH THE wiCICLE® WIRELESS DMX SYSTEM

In addition to the unbridled thrill you already received the first time you plugged in 

your fixture, you’ll be delighted to know that This fixture also works seamlessly with our 

wiCICLE® Wireless DMX system, without additional power.

• ONLY fixtures bearing this logo are certified for use with the wiCICLE® without external 

power.

• Unauthorized modification and/or using the wiCICLE® with 

unapproved fixtures may cause damage to the wiCICLE® or 

fixture.  UNDER NO CIRCUMSTANCES IS BLIZZARD LIGHTING 

RESPONSIBLE FOR ANY DAMAGE FROM SUCH OPERATION.

• Fixtures bearing the above logo MUST only use cable and connectors which separate 

chassis/case ground from cable shielding.  Cabling with the shield connected to the connec-

tor’s case/chassis may cause malfunction and damage to the wiCICLE® or fixture.

• wiCICLE® transmitters have additional power requirements and therefore cannot be 

powered directly from the fixture.  You will need to utilize the supplied AC/DC adaptor to 

drive wiCICLE® transmitters in your system.

Summary of Contents for Puck QFX

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright 2012...

Page 2: ...ar Connections 7 3 Setup 8 Fuse Replacement 8 Connecting A Bunch Of Puck QFX LED PAR Cans 8 Data DMX Cables 8 Using this fixture with the wiCICLE Wireless DMX System 8 4 Operating Adjustments 10 Contr...

Page 3: ...if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for you...

Page 4: ...re servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operat...

Page 5: ...e Puck QFX Flat LED PAR Fixture Main FEATURES Superior RGBW color mixing via 12 x 10 watt quad color RGBW LED s DMX controllable full panel and 4 pixel effects 3 LED s per pixel User selectable 3 4 9...

Page 6: ...rams 5 Speed Contol Slow Fast 6 Pixel Effects 7 Pixel Color Adjustment 8 Pixel Speed Contol Slow Fast 9 Microphone Sensitivity Slow Fast DMX Quick Reference 4 Channel Mode Channel What It Does 1 Red I...

Page 7: ...ight c 2012 Blizzard Lighting LLC Figure 1 The Puck QFX Pin Up Picture Ridiculously thin 10 Watt Quad Color LED s Figure 2 The Rear Connections AC Power In Out DMX In DMX Out LED Control Panel Microph...

Page 8: ...ions for EIA RS 485 applications Standard microphone cables will probably be OK but note that they cannot transmit DMX data as reliably over long distances In any event the cable should have the follo...

Page 9: ...should illuminate 2 Connect the AC DC adaptor to the the wiCICLE Transmitter and verify it is receiving power the STATUS LED should illuminate 3 Press the RECESSED SELECTOR BUTTON on the Transmitter t...

Page 10: ...through menu items and numbers in ascending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu map on pag...

Page 11: ...ENS 0 100 Microphone Sensitivity Low High SHND SOUN Sound Active Modes SOU1 Sound Active Mode 1 Color change off when silent SOU2 Sound Active Mode 2 Color change stop when silent SOU3 Sound Active Mo...

Page 12: ...to navigate to SOUN and press ENTER Finally use the UP DOWN buttons to navigate to either SOU1 SOU2 SOU3 or SOU4 Press the ENTER button to confirm your choice See page 11 menu structure for descriptio...

Page 13: ...e Color 6 Red White Color 7 Green Blue Color 8 Green White Color 9 Blue White Color 10 R G B Color 11 G B W Color 12 R B W Color 13 R G W Color 14 R G B W Color 15 4 000 016 017 095 096 175 176 195 19...

Page 14: ...is in the correct position if applicable Also check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicabl...

Page 15: ...al 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of t...

Page 16: ...satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending...

Page 17: ...25 degrees 29 degree field Luminous Intensity 1 Meter 2 Meter ALL 16 000 Lux 4 520 Lux Red 3 000 Lux 860 Lux Green 4 550 Lux 1 280 Lux Blue 5 390 Lux 1 520 Lux White 4 410 Lux 1 250 Lux Thermal Max Op...

Page 18: ...Page 18 The Puck QFX Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Page 19: ...Page 19 The Puck QFX Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: