6.)
AR2.S
- Architectural Mode #2 w/strobe (RGBAW, 7-Ch.)
Channel
Value
What It Does
1
000 <--> 255 Master Dimmer (0% <--> 100%)
2
000 <--> 255 Red Intensity (0% <--> 100%)
3
000 <--> 255 Green Intensity (0% <--> 100%)
4
000 <--> 255 Blue Intensity (0% <--> 100%)
5
000 <--> 255 Amber Intensity (0% <--> 100%)
6
000 <--> 255 White Intensity (0% <--> 100%)
7
000 <--> 255 Strobe
7.)
HSV
- Hue, Saturation, Value (3-Ch.)
Channel
Value
What It Does
1
000 <--> 255 Hue (0% <--> 100%)
2
000 <--> 255 Saturation (0% <--> 100%)
3
000 <--> 255 Brightness (0% <--> 100%)
ID
ID Address Selection
ID Address mode allows you to utilize up to 2,574 fixtures on only 1 DMX
universe while maintaining full individual control over each fixture. You can
enable or disable ID address operation within the
SET
menu. Control settings
are found in
STAG
mode, channel 11.
(see stage mode table on page 12)
.
•
Id.01 - Id.66
- Sets the ID# for the fixture.
TEMP
Temperature Functions
Allows the user to set a temperature protection cutoff (default is 85 degrees
Celsius), and displays the current fixture temperature.
•
CURR
- Displays current temperature.
•
•
TOP
- Sets the max temperature before shutoff (0-150, 85=default).
Summary of Contents for ProPar V12
Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 ...
Page 22: ...Page 22 ProPar V12 Manual Rev A 2013 Blizzard Lighting LLC This page intentionally left blank ...
Page 23: ...This page intentionally left blank ...
Page 24: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...