Blizzard Lighting ProPar Seven.6 User Manual Download Page 14

Page 14

ProPAR 7.6 Manual Rev. A  

 

 

© 2014 Blizzard Lighting, LLC

DMX Values In-Depth (11-Channel Mode)

Channel Value

What It Does

1

000 <--> 255

Dimmer (0% <--> 100%)

2

000 <--> 255

Red Intensity (0% <--> 100%)

3

000 <--> 255

Green Intensity (0% <--> 100%)

4

000 <--> 255

Blue Intensity (0% <--> 100%)

5

000 <--> 255

Amber Intensity (0% <--> 100%)

6

000 <--> 255

White Intensity (0% <--> 100%)

7

000 <--> 255

UV Intensity (0% <--> 100%)

8

 

000 <--> 255

Strobe

Strobe (Slow <--> Fast)

9

000 <--> 020

021 <--> 041

042 <--> 062

063 <--> 084

085 <--> 105

106 <--> 126

127 <--> 147

148 <--> 168

169 <--> 189

190 <--> 210

211 <--> 231

231 <--> 255

Auto Program 1 (Chase Pattern)

Auto Program 2 (Fade Pattern)

Custom Program 1

Custom Program 2

Custom Program 3

Custom Program 4

Custom Program 5

Custom Program 6

Sound Active 1

Sound Active 2

Sound Active 3

Sound Active 4

10

000 <--> 255

Program Speed (0% <--> 100%)

11

000 <--> 127

128 <--> 255

16-bit Dimmer

32-Bit Dimmer

DMX Values In-Depth (8-Channel Mode)

Channel Value

What It Does

1

000 <--> 255

Dimmer (0% <--> 100%)

2

000 <--> 255

Red Intensity (0% <--> 100%)

3

000 <--> 255

Green Intensity (0% <--> 100%)

4

000 <--> 255

Blue Intensity (0% <--> 100%)

5

000 <--> 255

Amber Intensity (0% <--> 100%)

6

000 <--> 255

White Intensity (0% <--> 100%)

7

000 <--> 255

UV Intensity (0% <--> 100%)

8

000 <--> 127

128 <--> 255

16-bit Dimmer

32-Bit Dimmer

Summary of Contents for ProPar Seven.6

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2014...

Page 2: ...l Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Set The Startin...

Page 3: ...on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device ca...

Page 4: ...cing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at amb...

Page 5: ...Beam Angle 25 4 580 Lux 1m 1 240 Lux 2m full on 1000hz flicker free LED drivers Light Source 7 15 watt 6 in 1 LEDs 100 000 hours CONTROL USITT DMX 512 3 6 8 11 Channels 3 pin Input Output LED 4 button...

Page 6: ...lizzard Lighting LLC Figure 1 The ProPar Seven 6 Pin Up Picture 7x 6 in 1 RGBAW UV LEDs Powder Coated Cast Aluminum Enclosure Dual Mounting Brackets Figure 2 The Rear Connections Menu Buttons LED Menu...

Page 7: ...res on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in dete...

Page 8: ...to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Conn...

Page 9: ...perating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enoug...

Page 10: ...menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu map on page 11 Wh...

Page 11: ...uto modes 1 2 ProG Built in programs 1 6 Edit Pr 01 Pr 06 Custom programs 1 6 Scene 1 30 SoUd Snd 1 Sound active modes 1 4 Stat r 000 r 255 Red dimmer 0 100 G 000 G255 Green dimmer 0 100 b 000 b255 Bl...

Page 12: ...ory installed programs at user selectable speeds Built In Static Colors 1 Navigate the menu using the UP DOWN button until you reach chAS 2 Push the ENTER button 3 Use the UP DOWN buttons to navigate...

Page 13: ...U White or u UV then press ENTER 4 Using the UP DOWN buttons select the maximum level for each color between x 000 x 255 000 off then press ENTER to confirm Manual Color Adjustment Global Using this...

Page 14: ...190 210 211 231 231 255 Auto Program 1 Chase Pattern Auto Program 2 Fade Pattern Custom Program 1 Custom Program 2 Custom Program 3 Custom Program 4 Custom Program 5 Custom Program 6 Sound Active 1 S...

Page 15: ...position if applicable No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of spee...

Page 16: ...n mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the firs...

Page 17: ...factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service...

Page 18: ...000 hours Optical Beam Angle 25 degree Luminous Intensity Lux m Red Green Blue Amber White UV ALL 1m 1 000 1 361 1 259 671 2 070 327 4 580 2m 305 355 356 188 590 95 1 240 Thermal Max Operating Temp 1...

Page 19: ...This page intentionally left blank...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: