background image

Page 11

ProPar I7 User Manual - Rev. A  

 

 

(c) 2016 Blizzard Lighting, LLC

Control Panel Menu Structure

Address

001-512

To choose the DMX address

Intro

Reset

Reset the fixture

DMX512

DMX mode

Auto1

Auto program 1

Auto2

Auto program 2

Auto3

Auto program 3

Sound1

Sound active mode 1

Sound2

Sound active mode 2

Slave

Slave mode

Mode

23CH

To run in 23-channel mode

51CH

To run in 51-channel mode

Test

All

Test motors and LEDs

LED

Test LEDs

Set

Disp. 

set

Key 

lock

On/Off: Unlock code is 

<UP>, <DOWN>, <UP>, 

<DOWN>, <ENTER>

Dipflas

On/Off: Display will flash if DMX signal is lost

Shuttime

Set to shut off display after 2-60 minutes of inactivity

Info

Time If. Power on Hours since powered on

Ttl Life

Total running hours

Last Run Last run hours

Soft Ver

Displays software version information

LED Identification

1.) The drawing below illustrates each LEDs assigned ID number for pixel mapping:

Summary of Contents for ProPar I7

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2016 ...

Page 2: ...rs 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 11 Control Panel Menu Structure 11 LED Identification 11 DMX Mode 12 Set the Starting DMX Address 12 Select the DMX Channel Mode 12 Slave Mode 12 Auto Mode 12 Sound Active Mode 12 Test Mode 12 Menu Key Lock 12 Test Mode 12 Men...

Page 3: ...power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your u...

Page 4: ... servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled peo...

Page 5: ...rol panel Operating Modes Standalone Master Slave Auto Sound Active DMX Quick Reference 23 51 Channel Modes 23CH 51CH What It Does 1 1 Red Intensity 0 100 2 2 Green Intensity 0 100 3 3 Blue Intensity 0 100 4 4 White Intensity 0 100 5 5 Linear CTO 6 6 Macro Color 7 7 Strobe 8 8 Dimmer 0 100 9 9 Dimming Mode 10 10 Reset 11 11 Zoom 12 12 Zoom Rotation 13 13 Shape Selection 14 14 Shape Speed 15 15 Sha...

Page 6: ...r I7 Pin Up Picture 7 15W RGBW 4 in 1 LEDs Dual Mounting Brackets Figure 2 The Rear Connections Fuse Cover Power Out 3 Pin DMX Out 4 Button LCD Control Panel 3 Pin DMX In Power In Safety Loop Locking Knobs Heavy Duty Composite Housing Zoomable and Rotatable Lens with 4 60 Beam Angle ...

Page 7: ...e serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can carry a high qualit...

Page 8: ...like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the ...

Page 9: ...ck the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixtu...

Page 10: ...s in ascending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LCD Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER U...

Page 11: ... run in 23 channel mode 51CH To run in 51 channel mode Test All Test motors and LEDs LED Test LEDs Set Disp set Key lock On Off Unlock code is UP DOWN UP DOWN ENTER Dipflas On Off Display will flash if DMX signal is lost Shuttime Set to shut off display after 2 60 minutes of inactivity Info Time If Power on Hours since powered on Ttl Life Total running hours Last Run Last run hours Soft Ver Displa...

Page 12: ...ER button to confirm your selection Sound Active Mode 1 Navigate the main menu until you reach Intro press ENTER 2 Use the UP DOWN buttons to select Sound1 Sound3 3 Press the ENTER button to confirm your selection Test Mode 1 Navigate the main menu until you reach Test press ENTER 2 Use the UP DOWN buttons to select All motors and LEDs or LED LEDs only 3 Press the ENTER button to confirm your sele...

Page 13: ...Gamma 1 Linear Curve2 Gamma 1 5 Curve3 Gamma 2 Curve4 Gamma 4 S Curve Reserved 10 000 025 026 076 077 127 128 255 Reset No Function Zoom Reset No Function Complete Reset 11 000 255 Zoom narrow wide 12 000 127 128 190 191 192 193 255 Zoom Rotation Incremental Rotation Clockwise Rotation fast slow Stop Counterclockwise Rotation slow fast 13 000 255 Shape Selection 14 000 255 Shape Speed 15 000 255 S...

Page 14: ...230 160 0 69 114 Deep Amber 104 255 166 0 0 115 116 Orange 105 255 122 0 0 117 Light Rose 107 255 141 31 0 118 English Rose 108 255 148 23 0 119 Light Salmon 109 255 138 31 0 120 Middle Rose 110 217 130 28 0 121 122 Dark Pink 111 255 109 33 0 123 124 Magenta 113 255 20 15 0 125 Peacock Blue 115 51 255 51 0 126 Med Blu Green 116 206 255 56 0 127 Steel Blue 117 206 255 56 0 128 Light Blue 118 74 255...

Page 15: ...pixels variable density and speed Yes 063 067 Rainbow 1 Variable speed N A 000 063 Angle 0 360 static 064 158 Max to min speed c cw rotation 159 160 Stop 161 255 Min to max speed cw rotation 000 255 Angle offset from 0 to 360 068 072 Rainbow 2 Fixed speed with variable color offset N A 000 063 Stop 064 158 c cw rota tion 159 160 Stop 161 255 cw rotation N A 073 077 Fan 3 arms N A 000 063 Angle off...

Page 16: ...255 Lens offset angle 0 00 degree Lens offset angle 0 06 degree Lens offset angle 3 87 degree Lens offset angle 3 94 degree Lens offset angle 4 00 degree Lens offset angle 0 00 degree Troubleshooting Symptom Solution No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable No Power Check fuse AC cord and circuit for malfunction Blown Fuse C...

Page 17: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting chann...

Page 18: ... a unit in for service But like any com plex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture should you ll need to obtain a Return Authorization RA Don t worry this is easy Just go to our website and open a support ticket at www blizzardlighting com support and we ll i...

Page 19: ... Blue White All 1m 4 31 010 17 520 19 010 27 320 47 400 2m 4 5 800 7 790 9 050 11 880 21 360 1m 60 739 882 922 1 202 2 473 2m 60 203 227 239 320 543 Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 23 51 channel DMX modes Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Auto Sound Active Other Inform...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Reviews: