Blizzard Lighting Mezmerizor 4FX User Manual Download Page 4

Page 4

Mezmerizor™ Manual - Rev. A  

 

 

(c) 2013 Blizzard Lighting, LLC

LASER SAFETY REQUIREMENTS

Lasers are one of the coolest effects available, and when they are used appropri-

ately, they will be fun, legal and harmless.  To make sure that is the case...

• Always set up and install all laser effects so that all laser light is at least 3 me

-

ters (9.8 feet) above the floor on which people can stand.

• After setting up, and before public use, test laser to ensure proper function. Do 

not use if any defect is detected. Do not use if laser emits only one or two laser 

beams rather than dozens/hundreds, as this could indicate damage to the dif-

fraction grating optic, and could allow emission of higher laser levels above Class 

3R.

• 

NEVER

 point lasers at people or animals. Never look into the laser aperture or 

laser beams.

• 

NEVER

 point lasers in areas in which people can potentially get exposed, such 

as uncontrolled balconies, etc.

• 

NEVER 

point lasers at highly reflective surfaces, such as windows, mirrors and 

shiny metal. Even laser reflections can be hazardous.

• 

NEVER

 point a laser at aircraft, 

this is a federal offense!

• 

NEVER

 point un-terminated laser beams into the sky.

• 

NEVER

 expose the output optic (aperture) to cleaning chemicals.

• 

NEVER

 use laser if the laser appears to emit only one or two beams.

• 

NEVER

 use the laser if the housing is damaged, the housing is open, or if the 

optics appear damaged in any way.

• 

NEVER

 open the laser housing. The high laser power levels inside of the pro-

tective housing can start fires, burn skin and will cause instant eye injury.

• 

NEVER

 leave this device running unattended.

The operation of a class 3R laser show is only allowed if the show is controlled 

by a skilled and well-trained operator, familiar with the data from this manual.  

The legal requirements for using laser entertainment products vary from country 

to country. The user is responsible for the legal requirements at the location/

country of use.

Summary of Contents for Mezmerizor 4FX

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 MEZMERIzoR4FX TM...

Page 2: ...up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Mezmerizors 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking...

Page 3: ...e fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a...

Page 4: ...get exposed such as uncontrolled balconies etc NEVER point lasers at highly reflective surfaces such as windows mirrors and shiny metal Even laser reflections can be hazardous NEVER point a laser at...

Page 5: ...settings Polished blue aluminum casing w hanging bracket Compact and lightweight it kept its new year s resolution Laser Specifications Color Wavelength Power Output Red 650nm 100mW Green 532nm 50mW...

Page 6: ...izor Pin Up Picture Attractive Blue Colored Aluminum Casing Secure Mounting Bracket Adjustment Screws Figure 2 The Rear Connections Laser Output Aperture Power Indicator Microphone Mic Indicator On Of...

Page 7: ...ixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640...

Page 8: ...e to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Con...

Page 9: ...Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is eno...

Page 10: ...et dipswitch 10 to OFF 2 Connect DMX OUT of controller to DMX IN of 1st fixture Daisy chain DMX OUT to DMX IN for any additional fixtures 3 Use dipswitches 1 9 to set the fixtures Starting DMX Address...

Page 11: ...on Cycle Bird Flying Animation Cycle Dinosaur Walk Animation Cycle 50 Static Patterns Running Animation Cycle Feline Animation Cycle Flying Bird Animation Cycle 4 Pattern 1 Color 000 001 002 069 070 0...

Page 12: ...o X Fluctuation Auto Square Fluctuation Lower Corner Movement 10 X Axis Rotation 000 150 151 255 Manual Position Auto Position Spin 11 Y Axis Rotation 000 150 151 255 Manual Position Auto Position Spi...

Page 13: ...ission standard over two wires As with microphone cables a grounded cable shield is used to prevent interference with other signals There are five pins on a DMX connector a wire for ground cable shiel...

Page 14: ...faction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a uni...

Page 15: ...650nm 100mW Green 532nm 50mW Blue 470nm 100mW White all 250mW Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 15 Channel Input 3 pin XLR Male...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...