Fixture Linking (Master/Slave Mode)

1.  Connect the (male) 3 pin connector side of the 

DMX cable to the output (female) 3 pin connector of 

the first fixture.

2.  Connect the end of the cable coming from the 

first fixture which will have a (female) 3 pin connec

-

tor to the input connector of the next fixture con

-

sisting of a (male) 3 pin connector. Then, proceed 

to connect from the output as stated above to the 

input of the following fixture and so on.

A quick note:  

Often, 

the setup for Master-

Slave and Standalone 

operation requires that 

the first fixture in the 

chain be initialized for 

this purpose via either 

settings in the control 

panel or DIP-switches. 

Secondarily, the fixtures 

that follow may also re-

quire a slave setting. 

Check the “

Operating Adjustments

” section in this manual for com-

plete instructions for this type of setup and configuration.

Mounting & Rigging

This fixture may be mounted in any SAFE position provided there is 

enough room for ventilation.

It is important never to obstruct the fan or vents pathway. Mount the 

fixture using a suitable “C” or “O” type clamp.  The clamp should be 

rated to hold at least 10x the fixture’s weight to ensure structural sta

-

bility.  Do not mount to surfaces with unknown strength, and ensure 

properly “rated” rigging is used when mounting fixtures overhead.

Adjust the angle of the fixture by loosening both knobs and tilting the 

fixture. After finding the desired position, retighten both knobs.

•  When selecting installation location, take into consideration lamp 

replacement access (if applicable) and routine maintenance.
•  Safety cables MUST ALWAYS be used.

•  Never mount in places where the fixture will be exposed to rain, 

high humidity, extreme temperature changes or restricted ventilation.

Summary of Contents for Lo-Pro Flux

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015...

Page 2: ...up 7 Fuse Replacement 7 Connecting A Bunch Of Stiletto s 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9...

Page 3: ...el on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device...

Page 4: ...cing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at amb...

Page 5: ...ects 160 degree beam angle 3 pin DMX in out connections 5 pin DMX in out connections PowerCON compatible AC in out Dual mounting brackets for amazing support DMX Quick Reference 3 8 11 Channel Modes C...

Page 6: ...in Up Picture 288 x 5W SMD5050 LEDs Figure 2 The Rear Connections PowerCon Compatible In Out LED Display Touring grade compact shell Two piece mounting yoke 4 button Control Panel Safety Cable Attachm...

Page 7: ...a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteriorat...

Page 8: ...o build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connec...

Page 9: ...rating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough...

Page 10: ...menu options in descending order Used to select and store the current menu or option within a menu Access control panel functions using the four panel buttons located directly underneath the LED Disp...

Page 11: ...grams Soun Sound Control NAnF Manual Control OFF Hit Enter to confirm NAno Manual Control ON Hit Enter to confirm NAno F 000 000 255 Strobe Rate 1 000 000 255 Section 1 Intensity 2 000 000 255 Section...

Page 12: ...r Clockwise Thunder Strobe Pixel Sections Turn off Clockwise Pixel Sections 1 5 3 7 Alternate Pixel Sections move Counter Clockwise Auto Pixel Section Movement Clockwise Auto Pixel Section Movement Co...

Page 13: ...ections Turn off Counter Clockwise Thunder Strobe Pixel Sections Turn off Clockwise Pixel Sections 1 5 3 7 Alternate Pixel Sections move Counter Clockwise Auto Pixel Section Movement Clockwise Auto Pi...

Page 14: ...Check fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement V...

Page 15: ...mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first...

Page 16: ...tor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service Bu...

Page 17: ...ambient Control Protocol USITT DMX 512 DMX Channels 3 8 11 channels Input 3 pin 5 pin XLR Male Output 3 pin 5 pin XLR Female Other Information I won t be impressed with technology until I can downloa...

Page 18: ...Page 18 Lo Pro Flux Rev A c 2015 Blizzard Lighting LLC This page left intentionally blank...

Page 19: ...Page 19 Lo Pro Flux Rev A c 2015 Blizzard Lighting LLC This page left intentionally blank...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: