Blizzard Lighting Laser Blade G Manual Download Page 7

Page 7

Laser Blade™ G Manual - Rev. B    

 

© 2020 Blizzard Lighting, LLC

Fuse Replacement

The Laser Blade™ G utilizes a high-output switch-mode power supply with an 

internal fuse.  Under normal operating conditions, the fuse should not require 

replacement.  The fuse is field replaceable, however it is an advanced procedure 

suited to qualified individuals.  Should the fuse require replacement, please 

contact Blizzard Lighting for instructions, or to return your unit for service.

Connecting A Bunch of Laser Blade™ G Fixtures

You will need a serial data link to run light shows using a DMX-512 controller 

or to run shows on two or more fixtures set to sync in master/slave operating 

mode. The combined number of channels required by all the fixtures on a serial 

data link determines the number of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. Also, 

connecting more than 32 fixtures on one serial data link without the use of a 

DMX optically-isolated splitter may result in deterioration of the digital DMX 

signal. The maximum recommended cable-run distance is 500 meters (1640 

ft).  The maximum recommended number of fixtures on a serial data link is 32 

fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-grade 

cables that can carry a high quality signal and are less prone to electromagnetic 

interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but note that 

they cannot transmit DMX data as reliably over long distances.  In any event, 

the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing a fuse, disconnect the power cord. 

ALWAYS replace with the same type and rating of fuse.

3. SETUP

Summary of Contents for Laser Blade G

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2020...

Page 2: ...ement 7 Connecting A Bunch of Laser Blade G Fixtures 7 Data DMX Cabling 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting Up DMX Control 8 Fixture Linking M S Mode 9 Mounting Ri...

Page 3: ...p All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100...

Page 4: ...y get exposed such as uncontrolled balconies etc NEVER point lasers at highly reflective surfaces such as windows mirrors and shiny metal Even laser reflections can be hazardous NEVER point a laser at...

Page 5: ...ct for venues large and small Ready to use right out of the box Additional Features Rugged and well built It hits the gym regularly Lightweight and easily portable Clamp mounting bracket included Easy...

Page 6: ...Manual Rev B 2020 Blizzard Lighting LLC The Rear Connections Laser Blade G Pin Up Picture Head Arms Laser Output Aperture Control Panel Mic Sensitivity Microphone LED Indicator Power In Power Switch...

Page 7: ...connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run d...

Page 8: ...act between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity a...

Page 9: ...omplete instructions for this type of setup and configuration DMX OUT DMX IN First Fixture in Chain Next Fixture in Chain DMX OUT DMX IN Mounting Rigging This fixture may be mounted in any SAFE positi...

Page 10: ...a menu option To return to the previous option or menu without changing the value press the MENU button 4 OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the...

Page 11: ...le or No to disable Press ENTER to confirm Running Mode Settings Fine tune the position of either X Y or both 1 Navigate the menu to reach X Run Set or Y Run Set and press ENTER 2 Highlight Run for de...

Page 12: ...000 015 016 255 Group 1 On Off Laser off Laser on 7 000 028 029 255 Group 2 Pattern Selection No function laser is off 76 kinds of beam patterns 8 000 015 016 255 Group 2 On Off Laser off Laser on 9 0...

Page 13: ...0 127 128 159 160 191 192 223 224 255 Zoom No Function Manual zoom Auto zoom Auto zoom Auto zoom 16 000 063 064 127 128 191 192 255 Sine Wave Fluctuation No Function X fluctuation Y fluctuation X Y fl...

Page 14: ...That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But li...

Page 15: ...ertz Fuse 2A 250V Power Consumption 20W Light Source Laser Fat beam 50mW 532nm green DPSS Scanner 15kpss high speed optical scanner Laser Class Class 3R Thermal Max Operating Temp 104 degrees F 40 deg...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: