Blizzard Lighting Cyc Out User Manual Download Page 16

Page 16

Cyc Out™ User Manual Rev. D 

 

 

© 2017 Blizzard Lighting, LLC

Rate and Duration Details 

(continued)

DMX Value

Rate (ms)

Freq. (Hz)

Dur. (ms)

DMX Value

Rate (ms)

Freq. (Hz)

Dur. (ms)

84

172

5.81

255

170

83

11.98

513

85

170

5.88

258

171

82

12.12

516

86

168

5.95

261

172

82

12.12

519

87

166

6.02

264

173

81

12.27

522

88

164

6.1

267

174

81

12.27

525

89

162

6.17

270

175

80

12.42

528

90

160

6.25

273

176

80

12.42

531

91

158

6.33

276

177

79

12.56

534

92

156

6.41

279

178

79

12.56

537

93

154

6.49

282

179

78

12.69

540

94

152

6.58

285

180

78

12.69

543

95

151

6.62

288

181

78

12.69

546

96

150

6.67

291

182

77

12.89

549

97

149

6.71

294

183

77

12.89

552

98

148

6.76

297

184

76

13.02

555

99

147

6.8

300

185

76

13.02

558

100

146

6.85

303

186

76

13.02

561

101

145

6.9

306

187

75

13.23

564

102

144

6.94

309

188

75

13.23

567

103

142

7.04

312

189

74

13.37

570

104

140

7.14

315

190

74

13.37

573

105

138

7.25

318

191

74

13.37

576

106

136

7.35

321

192

73

13.59

579

107

134

7.46

324

193

73

13.59

582

108

132

7.58

327

194

72

13.74

585

109

130

7.69

330

195

72

13.74

588

110

128

7.81

333

196

72

13.74

591

111

127

7.87

336

197

71

13.97

594

112

126

7.94

339

198

71

13.97

597

113

125

8

342

199

70

14.12

600

114

124

8.06

345

200

70

14.12

603

115

123

8.13

348

201

70

14.12

606

116

122

8.2

351

202

69

14.37

609

117

121

8.26

354

203

69

14.37

612

118

120

8.33

357

204

69

14.37

615

119

119

8.4

360

205

68

14.56

618

120

118

8.47

363

206

68

14.56

621

121

117

8.55

366

207

68

14.56

624

122

116

8.62

369

208

67

14.75

627

123

115

8.7

372

209

67

14.75

630

124

114

8.77

375

210

67

14.75

633

125

113

8.85

378

211

66

14.95

636

126

112

8.93

381

212

66

14.95

639

127

111

9.01

384

213

66

14.95

642

128

110

9.09

387

214

66

14.95

645

129

109

9.17

390

215

65

15.22

648

130

109

9.17

393

216

65

15.22

651

131

109

9.17

396

217

65

15.22

654

132

109

9.17

399

218

64

15.43

657

133

108

9.22

402

219

64

15.43

660

134

108

9.22

405

220

64

15.43

663

135

107

9.3

408

221

63

15.65

666

136

107

9.3

411

222

63

15.65

669

137

106

9.39

414

223

63

15.65

672

138

106

9.39

417

224

63

15.65

675

139

105

9.48

420

225

62

15.95

678

140

105

9.48

423

226

62

15.95

681

141

104

9.57

426

227

62

15.95

684

142

104

9.57

429

228

61

16.18

687

143

103

9.71

432

229

61

16.18

690

144

102

9.8

435

230

61

16.18

693

145

101

9.9

438

231

60

16.42

696

146

100

10

441

232

60

16.42

699

147

99

10.1

444

233

60

16.42

702

148

98

10.2

447

234

60

16.42

705

149

97

10.31

450

235

59

16.95

708

150

96

10.42

453

236

58

17.24

711

151

95

10.53

456

237

57

17.54

714

152

94

10.64

459

238

56

17.86

717

153

93

10.75

462

239

55

18.18

720

154

92

10.87

465

240

54

18.52

723

155

91

10.99

468

241

53

18.87

726

156

90

11.11

471

242

52

19.23

729

157

89

11.17

474

243

51

19.61

732

158

89

11.17

477

244

50

20

735

159

88

11.3

480

245

49

20.41

738

160

88

11.3

483

246

48

20.83

741

161

87

11.43

486

247

47

21.28

744

162

87

11.43

489

248

46

21.74

747

163

86

11.56

492

249

45

22.22

750

164

86

11.56

495

250

44

22.73

753

165

85

11.7

498

251

43

23.26

756

166

85

11.7

501

252

42

23.81

759

167

84

11.83

504

253

41

24.39

762

168

84

11.83

507

254

40

25

765

169

83

11.98

510

255

40

25

768

Summary of Contents for Cyc Out

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2017 ...

Page 2: ... 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Slave Mode 12 Static Settings 12 Dimming Mode Settings 13 DMX Signal Loss Settings 13 Fan Mode Settings 13 Power Output Settings 13 Fixture Information...

Page 3: ...you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify t...

Page 4: ...n slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try t...

Page 5: ...uick Reference 4 5 8 10 15 16 28 Channel Modes 4CH 5CH 8CH 10CH 15CH 16CH 28CH What It Does 1 1 1 1 1 Master Intensity 0 100 1 Master Intensity 1 0 100 1 2 2 2 2 2 2 Red 1 Intensity 0 100 3 3 Red 1 Duration 0 255 4 4 Red 1 Rate 0 255 2 3 3 3 3 5 5 Green 1 Intensity 0 100 6 6 Green 1 Duration 0 255 7 7 Green 1 Rate 0 255 3 4 4 4 4 8 8 Blue 1 Intensity 0 100 9 9 Blue 1 Duration 0 255 10 10 Blue 1 Ra...

Page 6: ...1 The Cyc Out Pin Up Picture Figure 2 The Rear Connections Locking Adjustment Knob Mounting Bracket Stand Fuse Holder Power Switch AC Power Input 3 Pin DMX In Out 5 Pin DMX In Out 4 button Control Panel Cooling Fans 256 x R G B W 3W LEDs Barndoor Barndoor Zone 1 Zone 2 ...

Page 7: ...se of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can carry a high quality signal and are less prone to el...

Page 8: ...xture s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4 Data 2 Optional Secondary Data Link Pin 5 Pin 5 Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the controller ...

Page 9: ...y the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type...

Page 10: ...the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows the menu items you select from the menu map on page 11 When a menu function is selected the dis play will show immediately the first available option for the selected menu function To select a menu item press ENTER Use th...

Page 11: ...15 channel mode 16CH To run in 16 channel mode 28CH To run in 28 channel mode DIM dimming LIN Linear dimming curve SQR Square law curve ISQR Inverse square law curve SCUR S curve LIN Linear dimming curve smooth SQR Square law curve smooth ISQR Inverse square law curve smooth SCUR S curve smooth FAN ON Keep fan on continually SMART Automatic temperature controlled fan cooling OUTPUT MAX Max output ...

Page 12: ... is the master fixture and the following fixtures will follow the master Static Settings Create custom colors with individual R G B W level and strobe settings Intensity 1 Navigate the menu to reach STAT then press ENTER 2 Use the UP DOWN buttons to highlight MAST INT master intensity R INT red intensity G INT green intensity B INT blue intensity W INT white intensity and press the ENTER button 3 ...

Page 13: ...et the cooling fans to SMART cooling or continually ON 1 Use the MENU and UP DOWN buttons to navigate to SET and press ENTER then use the UP DOWN buttons to scroll to FAN and press ENTER 2 Now use the UP DOWN buttons to highlight ON continually on or SMART automatic temperature controlled and press ENTER Power Output Settings Manually set the power output mode 1 Use the MENU and UP DOWN buttons to...

Page 14: ...Duration 13 13 000 005 006 255 White 1 Rate Open Rate 6 000 255 Master Intensity 2 0 100 7 14 000 255 Red 2 Intensity 0 100 15 000 255 Red 2 Duration 16 000 005 006 255 Red 2 Rate Open Rate 8 17 000 255 Green 2 Intensity 0 100 18 000 255 Green 2 Duration 19 000 005 006 255 Green 2 Rate Open Rate 9 20 000 255 Blue 2 Intensity 0 100 21 000 255 Blue 2 Duration 22 000 005 006 255 Blue 2 Rate Open Rate...

Page 15: ...68 214 4 67 207 27 570 1 75 84 69 211 4 74 210 28 560 1 79 87 70 208 4 81 213 29 540 1 85 90 71 205 4 88 216 30 500 2 93 72 200 5 219 31 490 2 04 96 73 197 5 06 222 32 480 2 08 99 74 195 5 13 225 33 460 2 17 102 75 192 5 19 228 34 440 2 27 105 76 190 5 26 231 35 430 2 33 108 77 187 5 33 234 36 420 2 38 111 78 185 5 41 237 37 410 2 44 114 79 182 5 48 240 38 400 2 5 117 80 180 5 56 243 39 390 2 56 1...

Page 16: ...8 14 56 624 122 116 8 62 369 208 67 14 75 627 123 115 8 7 372 209 67 14 75 630 124 114 8 77 375 210 67 14 75 633 125 113 8 85 378 211 66 14 95 636 126 112 8 93 381 212 66 14 95 639 127 111 9 01 384 213 66 14 95 642 128 110 9 09 387 214 66 14 95 645 129 109 9 17 390 215 65 15 22 648 130 109 9 17 393 216 65 15 22 651 131 109 9 17 396 217 65 15 22 654 132 109 9 17 399 218 64 15 43 657 133 108 9 22 40...

Page 17: ...ns on a DMX connector a wire for ground cable shield two wires for Primary communication which goes from a DMX source to a DMX receiver and two wires for a Secondary communication which goes from a DMX receiver back to a DMX source Generally the Secondary channel is not used so data flows only from sources to receiv ers Hence most of us are most familiar with DMX 512 as being employer over typical...

Page 18: ...actor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture ...

Page 19: ...Protocol USITT DMX 512 DMX Channels 4 5 8 10 15 16 28 channel Input Output 3 5 pin XLR Male Female Other Operating Modes Standalone Master Slave Mode Warranty 2 year limited warranty does not cover malfunction caused by damage to LEDs DISCLAIMER The power connector fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG Neutrik USA and their r...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Reviews: