Blizzard Lighting Cyc Out User Manual Download Page 1

Blizzard Lighting, LLC

www.blizzardlighting.com

Waukesha, WI USA

Copyright (c) 2017

Summary of Contents for Cyc Out

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2017 ...

Page 2: ... 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Slave Mode 12 Static Settings 12 Dimming Mode Settings 13 DMX Signal Loss Settings 13 Fan Mode Settings 13 Power Output Settings 13 Fixture Information...

Page 3: ...you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify t...

Page 4: ...n slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try t...

Page 5: ...uick Reference 4 5 8 10 15 16 28 Channel Modes 4CH 5CH 8CH 10CH 15CH 16CH 28CH What It Does 1 1 1 1 1 Master Intensity 0 100 1 Master Intensity 1 0 100 1 2 2 2 2 2 2 Red 1 Intensity 0 100 3 3 Red 1 Duration 0 255 4 4 Red 1 Rate 0 255 2 3 3 3 3 5 5 Green 1 Intensity 0 100 6 6 Green 1 Duration 0 255 7 7 Green 1 Rate 0 255 3 4 4 4 4 8 8 Blue 1 Intensity 0 100 9 9 Blue 1 Duration 0 255 10 10 Blue 1 Ra...

Page 6: ...1 The Cyc Out Pin Up Picture Figure 2 The Rear Connections Locking Adjustment Knob Mounting Bracket Stand Fuse Holder Power Switch AC Power Input 3 Pin DMX In Out 5 Pin DMX In Out 4 button Control Panel Cooling Fans 256 x R G B W 3W LEDs Barndoor Barndoor Zone 1 Zone 2 ...

Page 7: ...se of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can carry a high quality signal and are less prone to el...

Page 8: ...xture s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4 Data 2 Optional Secondary Data Link Pin 5 Pin 5 Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the controller ...

Page 9: ...y the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type...

Page 10: ...the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows the menu items you select from the menu map on page 11 When a menu function is selected the dis play will show immediately the first available option for the selected menu function To select a menu item press ENTER Use th...

Page 11: ...15 channel mode 16CH To run in 16 channel mode 28CH To run in 28 channel mode DIM dimming LIN Linear dimming curve SQR Square law curve ISQR Inverse square law curve SCUR S curve LIN Linear dimming curve smooth SQR Square law curve smooth ISQR Inverse square law curve smooth SCUR S curve smooth FAN ON Keep fan on continually SMART Automatic temperature controlled fan cooling OUTPUT MAX Max output ...

Page 12: ... is the master fixture and the following fixtures will follow the master Static Settings Create custom colors with individual R G B W level and strobe settings Intensity 1 Navigate the menu to reach STAT then press ENTER 2 Use the UP DOWN buttons to highlight MAST INT master intensity R INT red intensity G INT green intensity B INT blue intensity W INT white intensity and press the ENTER button 3 ...

Page 13: ...et the cooling fans to SMART cooling or continually ON 1 Use the MENU and UP DOWN buttons to navigate to SET and press ENTER then use the UP DOWN buttons to scroll to FAN and press ENTER 2 Now use the UP DOWN buttons to highlight ON continually on or SMART automatic temperature controlled and press ENTER Power Output Settings Manually set the power output mode 1 Use the MENU and UP DOWN buttons to...

Page 14: ...Duration 13 13 000 005 006 255 White 1 Rate Open Rate 6 000 255 Master Intensity 2 0 100 7 14 000 255 Red 2 Intensity 0 100 15 000 255 Red 2 Duration 16 000 005 006 255 Red 2 Rate Open Rate 8 17 000 255 Green 2 Intensity 0 100 18 000 255 Green 2 Duration 19 000 005 006 255 Green 2 Rate Open Rate 9 20 000 255 Blue 2 Intensity 0 100 21 000 255 Blue 2 Duration 22 000 005 006 255 Blue 2 Rate Open Rate...

Page 15: ...68 214 4 67 207 27 570 1 75 84 69 211 4 74 210 28 560 1 79 87 70 208 4 81 213 29 540 1 85 90 71 205 4 88 216 30 500 2 93 72 200 5 219 31 490 2 04 96 73 197 5 06 222 32 480 2 08 99 74 195 5 13 225 33 460 2 17 102 75 192 5 19 228 34 440 2 27 105 76 190 5 26 231 35 430 2 33 108 77 187 5 33 234 36 420 2 38 111 78 185 5 41 237 37 410 2 44 114 79 182 5 48 240 38 400 2 5 117 80 180 5 56 243 39 390 2 56 1...

Page 16: ...8 14 56 624 122 116 8 62 369 208 67 14 75 627 123 115 8 7 372 209 67 14 75 630 124 114 8 77 375 210 67 14 75 633 125 113 8 85 378 211 66 14 95 636 126 112 8 93 381 212 66 14 95 639 127 111 9 01 384 213 66 14 95 642 128 110 9 09 387 214 66 14 95 645 129 109 9 17 390 215 65 15 22 648 130 109 9 17 393 216 65 15 22 651 131 109 9 17 396 217 65 15 22 654 132 109 9 17 399 218 64 15 43 657 133 108 9 22 40...

Page 17: ...ns on a DMX connector a wire for ground cable shield two wires for Primary communication which goes from a DMX source to a DMX receiver and two wires for a Secondary communication which goes from a DMX receiver back to a DMX source Generally the Secondary channel is not used so data flows only from sources to receiv ers Hence most of us are most familiar with DMX 512 as being employer over typical...

Page 18: ...actor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture ...

Page 19: ...Protocol USITT DMX 512 DMX Channels 4 5 8 10 15 16 28 channel Input Output 3 5 pin XLR Male Female Other Operating Modes Standalone Master Slave Mode Warranty 2 year limited warranty does not cover malfunction caused by damage to LEDs DISCLAIMER The power connector fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG Neutrik USA and their r...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Reviews: