Operating Instructions for Suspended Jacks
12
4.3
Compressed Air Supply
The compressed air supply must be provided via a maintenance unit consisting of water separator
and pressure reducer. Attach the maintenance unit directly to the jack.
•
Supply pressure: max. 10 bar
4.4
Electrical Connection
WARNING
Risk of injury and material damage due to electric shock
The electrical connection and the protective measures in force in the country are to be installed
and checked by a specialist.
The electrical connection must consist of a cable with a five-pin CEE coupling 16 A, which is
connected to a 400V/50Hz mains. A motor-protective circuit-breaker of 3.8 A must be present.
The manufacturer recommends a suitable cable suspension.
5
Commissioning
Before first operation:
Connect compressed air supply or electrical connection to the jack.
Check the hydraulic oil level. (
Perform the safety test. (
6
Operation
6.1
Load Handling Device
Safety notes
Do not stack extensions.
Always use the manufacturer’s original load handling devices with suitable spigots.
Support plate and extension
Traverse
Lift vehicles at one point.
Carefully lift vehicles at two points.
H
E