Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 15 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2200-SI_CANopenUM_REV1.0
e)
Set startup Indicator LED brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
05h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
à
min-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 05 10 00 00 00
Brightness = 25%
Keypad reply
595
Std
60 03 20 05 00 00 00 00
f)
Set startup backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
06h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
à
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 06 10 00 00 00
Brightness = 25%
Keypad reply
595
Std
60 03 20 06 00 00 00 00
20.
Object 2010h: Baud rate setting
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
10h
CAN Object 2010h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
00h
1000k
01h
Reserved (force to 125k)
02h
500k
03h
250k
04h
125k (Default)
05h
Reserved (force to 125k)
06h
50k
07h
20k
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format Message
Data
To Keypad
615
Std
2F 10 20 00 03 00 00 00
Baud rate = 250k