All responsibilities for defects or damages are hereby rejected if caused by: incorrect assembling of
the product, incorrect supply, use of lamps not suitable for this product, external agents. BLI/26.1.EN
Make sure NANO SENSE is installed by a professional electrician.
Do not install it on uneven and shaky surfaces.
V. Notes
Make sure there’s no object obstructing the field of detection.
Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
Please don´t open the case for your safety if you find the hitch after installation.
If there are some difference between instruction and the function the product has, please give priority to product and
sorry not to inform you additionally.
The load don´t work:
VI. Problems and solutions
Check the power and the load.
Whether the indicator light is turned on after sensing? If yes, please check load.
If the indicator light does not turn on after sensing, please check if the working light corresponds to the ambient light.
Please check if the working voltage corresponds to the power source.
The sensivity is poor:
Please check if in front of the detection window there are hinder that effect to receive the signals.
Please check the ambient temperature.
Please check if the signals source is in the detection fields.
Please check the installation height.
The sensor can´t shut automatically the load:
If there are continual signals in the detection fields.
If the time delay is set to the longest.
If the power correspond to the instruction.
If the air temperature change near the sensor, air condition or central heating, etc.