Blichmann BrewEasy Compact NPT Assembly Operation Maintenance Manual Download Page 2

BrewEasy™ Compact NPT V1 

© Blichmann Engineering, LLC 2021 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

2

What’s In the Box?

Part Number

Description

Quantity

G2Pot-10gal-NPT

G2 BoilerMaker™ 10 Gallon NPT Kettle

1

BE-001593-03

Grain Basket w/ Handle

1

aSightGlass-10gal

External Level Gauge

1

N/A

Basket Side Catches

2

N/A

Basket Hardware (Screw, Nut, & Washer)

4 of each

BE-000346-06

G2 Linear Flow Valve

1

BE-000503-00

Valve O-ring

1

BE-500004-00

Dip tube Fitting

1

KTL-004-02

Dip tube

1

KTL-005-05

Shaft Collar

1

N/A

Cleaning Toolkit

1

Optional Parts:
Heating Source Parts:

aBoilCoil-10gal-240V

BoilCoil™ 10 Gallon 240V Kit

1

Comes with 240V selection

aBoilCoil-10gal-120V

BoilCoil™ 10 Gallon 120V Kit

1

Comes with 120V selection

aHellFireBurner-FLR

Hellfire™ Burner

1

Comes with gas selection

Controller Parts:

aBrewCommander-240V

Electric 240V BrewCommander™

1

Comes with 240V selection

aBrewCommander-120V

Electric 120V BrewCommander™

1

Comes with 120V selection

aBrewCommander-Gas

Gas BrewCommander™

1

Optional with gas selection

BMA-002F-A

Brewmometer™ °F

1

Optional with gas selection

Recirculation Kit Parts:

BE-001996-00

Sparge Tube Assembly

1

BE-500004-00

Sparge Tube Port Bulkhead

1

BE-000067-00

Retaining O-ring

2

KTL-010-00

Retaining Washer

2

BE-000623-01

Wort Flow Meter

1

BE-000359-00

Silicone Hose

3ft

BE-000374-00

Reusable Hose Clamps

4

aRipTide-Pump

NPT RipTide™ Pump

1

BE-001997-00

1/2” QuickConnect™ Straight Barb

2

BE-001998-00

1/2” QuickConnect™ Elbow Barb

2

Therminator™ Cooling Kit:

HE-002-03

Therminator™

1

BE-001997-00

1/2” QuickConnect™ Straight Barb

3

BE-000359-00

Silicone Hose

6ft

aThruMometer-1/2

Thrumometer™

1

BE-000374-00

Reusable Hose Clamps

5

Immersion Chiller Kit:

AB-500067-00

Stainless Immersion Chiller

1

AB-500071-00

GTH Adapter - Brass

1

BE-000722-00

Hose Clamps - Stainless

3

BE-000730-01

3/8” Vinyl Hose

10ft

Whirlpool Kit:

aWhirlpool-G2

G2 Whirlpool Valve Assembly

1

Summary of Contents for BrewEasy Compact NPT

Page 1: ...act your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Important should specifically be followed to ensure satisfactory results with the product WARNING CAUTION IMPORTANT IMPORTANTINFORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION Brewing has inherent hazards and requires care focus and a mindset of safety an...

Page 2: ...ctric 240V BrewCommander 1 Comes with 240V selection aBrewCommander 120V Electric 120V BrewCommander 1 Comes with 120V selection aBrewCommander Gas Gas BrewCommander 1 Optional with gas selection BMA 002F A Brewmometer F 1 Optional with gas selection Recirculation Kit Parts BE 001996 00 Sparge Tube Assembly 1 BE 500004 00 Sparge Tube Port Bulkhead 1 BE 000067 00 Retaining O ring 2 KTL 010 00 Retai...

Page 3: ...e IMPORTANT If you are using the Blichmann HellFire Burner it comes configured for LP operation For use with natural gas you will need to install a natural gas conversion kit Step Two Next install the dip tube and drain valve on the front of your kettle To do so put the dip tube shaft collar fitting and the silicone white o ring into the bottom hole on the inside of the front of the kettle Then pl...

Page 4: ...ad tape is required Kettle wall Step Three In the lower hole on the back of the left of the kettle install the temperature probe as shown in the exploded view below If you purchased your system without a controller install the included Brewmometer in the 1 2 hole in the front of the kettle TEMPERATURE SENSOR ASSEMBLY Number Part Number Description 1 BE 000882 01 Sanitary Nut 2 BE 000882 01 Sanitar...

Page 5: ...We recommend that the straight barb QuickConnectors go on the hose that attaches to the drain valve and the pump inlet TIP On straight QuickConnectors leave approximately 1 8 of space between the QuickConnector nut and silicone hose before tightening the plastic clamp TIP Install the QuickConnectors is such a way that minimizes the potential for kinks that can restrict flow TIP Do not mount the pu...

Page 6: ...tion of the mashing period Set the flow of the pump to 0 75 gallons per minute and monitor this flow by checking the flow meter throughout the mash If desired after starch conversion you can heat the mash to the desired mash out temperature using the same method described in the Mashing section of this manual Allow the mash to rest at the mash out temperature for an adequate amount of time to stop...

Page 7: ...ing John Palmer s book How to Brew published by the Brewers Association before your first batch This manual is not intended to be a complete all grain brewing text IMPORTANT The quality of your finished beer will be directly related to the quality of your brewing water If you have especially hard water in your area it is strongly recommended that you dilute your tap water with distilled or reverse...

Page 8: ...ty or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited warranty 2 Blichmann Engineering make...

Reviews: