Blichmann Engineering Glycol Chiller Assembly Operation Maintenance Download Page 4

Glycol Chiller V1

© Blichmann Engineering, LLC 2019 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

4

OPERATION

The Blichmann Glycol Chiller pairs perfectly with our cooling kits.  This will allow 
you to cool up to 6 fermentors. Connect your hose to the submersible pump and 
place the submersible pump into the glycol. Run the hose out of the back of the 
glycol chiller as shown in 

Figure 4

. Run the excess cable from the submersible 

pump out the back of the glycol chiller and place into the cable management cover 
(

Figure 4

). Plug the temperature controller into the outlet on the glycol chiller and 

plug the submersible pump into the temperature controller as shown in 

Figure 5

Place the temperature probe from the temperature controller into the thermowell 
or tape it to the side of your fermentor and cover with insulation. Set the desired 
fermentation temperature on your temperature controller. 

Blichmann Temperature Controller

cool

SET

heat

62

Extra Cable Slack

Cable 

Management 

Cover

Glycol hose in 

and out

Figure 4

Figure 5

Summary of Contents for Glycol Chiller

Page 1: ...ese sections and understand them completely before use If you do not understand them or have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Caution can lead to equipment damage or unsatisfactory performance of the equipment Please read these sections thoroughly If you have any questions contact your retailer or Blichmann Engine...

Page 2: ... distiled water Plug in the glycol chiller Set the controller on the front of the glycol chiller to the desired temperature For maintaining fermentation temperatures set the chiller at least 5 degrees lower than the desired fermenta tion temperature For crashing a lower temperature may be required Assembly Caster Figure 1 Figure 3 Figure 2 Cable Management Cover Lid Screws on both sides Top Screws...

Page 3: ...ue of parameters System will save the modified temperature setting and exit the menu if no key is pressed in 5 seconds Press RST key and hold more than 3 seconds to automatically switch between F and C TECHNICAL SPECIFICATIONS PREPROGRAMMED PARAMETERS ERROR INFORMATION Indicator Light Status Function Cool Always on Compressor works Cool Flash Compressor output delay Code Function Set Range Unit De...

Page 4: ...cess cable from the submersible pump out the back of the glycol chiller and place into the cable management cover Figure 4 Plug the temperature controller into the outlet on the glycol chiller and plug the submersible pump into the temperature controller as shown in Figure 5 Place the temperature probe from the temperature controller into the thermowell or tape it to the side of your fermentor and...

Page 5: ...ing any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limi...

Reviews: