background image

 
 

4

Lid installation procedure: 

 

Place the extension lid upside down on the tank as shown in Fig. 5.  Install the U-shaped lid seal over 
the edge of the extension lid (not on the tank) with the small bead on the seal facing toward the lip of 
the tank as in Fig. 6.  Be sure the lid is centered on the tank as much as possible and that the 

alignment arrows match up.  Place the V-band clamp around the lid and tank lip and start the T-nut on 
the clamp stud.  The V-band clamp can be installed with either side up and with the clamp in any 

orientation.  Initially tighten the clamp to about 1/2” to ¾” (13-17mm) of gap between the band 
segments (Fig. 7), then, using a rubber or wood mallet, gently tap the outside perimeter of the V-band 
clamp to seat the clamp firmly and evenly all the way around the lid seal.  Start at the opposite side of 

the T-handle and work your way around to the handle.  

Retighten the clamp so the segment gap is 

less than 3/8” (13mm) as shown in Fig. 7 

 

Note:

 ALWAYS apply a dab of Vaseline or drop of oil on the threads of the draw bolt before each use to 

prevent wear and galling of the threads.  Galled or warn threads are NOT covered under warranty.  
 

 

 

  

 

 

 

 
Warning:

 Failure to correctly install and tighten the lid clamp can cause the lid to blow off during 

pressurization resulting in serious injury or death!  Please contact your Authorized Fermenator

TM

 

Distributor or Blichmann Engineering (www.BlichmannEngineering.com) if you have any questions 
about proper assembly.  Do not operate the unit until you are certain that you understand the proper 

installation procedure. 
 

 

Blow-off hose assembly 

 

The volume of CO2 flow generated during fermentation requires the use of a blow-off hose during 
primary fermentation.  Since this is a sealed blow-off system, it can also be used for secondary 

fermentation in lieu of an airlock.  Referring to Fig. 8 install the “P” clip on the tank as shown using a 
¼-20 bolt.  Note that a washer needs to be installed on the top of the P-clip.  The purpose of the P-clip 
is to hold the blow-off hose neatly in place.  If you are installing the leg extensions, an additional P-clip 

is provided.  Insert the black grommet in the extension lid as shown in Fig. 9, followed by the ¾ X ¾ 
barbed elbow.  Attach the hose and route it to a bucket filled with sanitizer (not included) as shown in 

Fig. 10.  A plastic ice-cream bucket with a lid works well, but be sure to cut an oversize hole in the lid to 
allow the CO2 gasses to escape. 

 

  

 

3/8” (13mm) Max Gap 

Fig. 7 

Fig. 6 

Fig. 5 

Bead 

Fig. 8 

Fig. 10 

Fig. 9 

Summary of Contents for Fermentator F3-42

Page 1: ...e marked L 3 Leg braces shorter braces 1 Bag misc 20 hardware 2 Arrow labels may be installed on lid and 27gal tank if purchased as a complete unit 1 P clip for blow off hose 1 Black grommet for blow off hose elbow 1 X barbed elbow nylon 1 X 6ft vinyl blow off hose trim to length desired About This Manual This is the supplementary manual for the F3 42 model and must be used in conjunction with the...

Page 2: ...r with the procedures and you are sure you have all the parts When you are ready to use the fermentor for an actual brewing session read the sanitizing procedures before assembling your FermenatorTM since many parts are sanitized before assembly Note that some of the components have not been pre assembled at the factory to prevent shipping damage Installing fittings Consult the Fermenator F3 27 ma...

Page 3: ...f the tank so a simple alignment procedure is needed to custom fit the extension lid to the tank Lid alignment procedure Place the extension lid on the tank without the lid seal in place Slowly rotate the lid making note of the gap between the lips as shown in Fig 3 The goal of the alignment procedure is to minimize the amount of gap between the lip of the tank and the lip of the extension lid Usi...

Page 4: ...warranty Warning Failure to correctly install and tighten the lid clamp can cause the lid to blow off during pressurization resulting in serious injury or death Please contact your Authorized FermenatorTM Distributor or Blichmann Engineering www BlichmannEngineering com if you have any questions about proper assembly Do not operate the unit until you are certain that you understand the proper inst...

Page 5: ...u will need additional cross braces as these are not included with the 27 gal leg extension kit Please contact your retailer for these braces and DO NOT operate without them Note it is not necessary to install the 90 deg elbow on the bottom dump assembly when using the leg extension kit This will allow the trub and yeast to flow more freely from the dump valve see Fig 11 Optional Casters Warning T...

Page 6: ...ng the unit Be sure all obstacles are out of the path of the Fermenator especially small objects which will wedge under the wheels and cause it to suddenly stop moving This will present a tipping hazard While moving keep both hands on the unit and move slowly to prevent accidental tipping When the unit is in its final location lock all the wheels by depressing the wheel lock Fig 19 with your foot ...

Page 7: ...s capacity is required for krausen space for beer and approximately 20 for wine Warning Do not use loose whole hops wood chips grape skins or other similar material in the fermentor Use a hop bag to prevent loose material from plugging the pressure relief valve or airlock which may cause a dangerous overpressure of the fermentor It is highly recommended that you use a blow off tube for primary fer...

Page 8: ...e by way of state or federal law including any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded ...

Reviews: