Operation: 

The BrewMometer™ utilizes a unique dial-face that 

guides the homebrewer through the different 
stages of the brewing process. This helps to 

eliminate errors and to develop consistency in your 

brews. Since many of the procedures and 

properties of beer are subjective, the selected 

temperatures should be used as guidelines, not 
hard limits.  

Reading the BrewMometer™

 

Dial-face 

The BrewMometer™

 

dial-face (shown in Fig. 6) 

contains all of the commonly used brewing 

processes and associated temperature ranges. 
Each process contains an “ideal” temperature, 

indicated by an arrow, and an acceptable range, 

indicated by a box. The brewing process is 

indicated inside of the box. 

Fig. 6 

Ideal Temp 

Acceptable 

Range 

Summary of Contents for BrewMometer BMA-002F-04

Page 1: ... you have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Assembly Installation Caution Prior to installing the BrewMometer select a position on the kettle that is high enough to be out of the direct heat from the burner but low enough to measure approximately in the middle of the liquid for a better temperature accuracy Caution As with any bime...

Page 2: ...l can be used on the back side of the hole to remove burrs and sharp edges Caution Use wrenches on BOTH sides of the kettle do not tighten by holding the dial face of the BrewMometer or you will damage the thermometer Use care not to hit the small calibration screw on the back side of the thermometer Install the O ring over the 20 UNF threaded portion of the BrewMometer and into the O ring groove ...

Page 3: ...most accurate method is to calibrate the thermometer with another known highly accurate thermometer Most digital thermometers utilize thermocouples and have a tolerance of about 3o F In practice digital thermometers are usually accurate to within 1o F Glass laboratory thermometers are ideal if available Place both thermometers in hot tap water swirling constantly and allow sufficient time for both...

Page 4: ...develop consistency in your brews Since many of the procedures and properties of beer are subjective the selected temperatures should be used as guidelines not hard limits Reading the BrewMometer Dial face The BrewMometer dial face shown in Fig 6 contains all of the commonly used brewing processes and associated temperature ranges Each process contains an ideal temperature indicated by an arrow an...

Page 5: ...manufacturing defects in material and workmanship or any other reason 4 Any performance of repairs after the warranty coverage period has expired or performance of repairs regarding anything excluded from coverage after this limited warranty 5 Shall be considered good will repairs and they will not alter the terms of this limited warranty or extend any warranty coverage period 6 Venue for any lega...