background image

BrewEasy™ Compact Tri-Clamp V1 

© Blichmann Engineering, LLC 2021 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

3

Set-Up

Step One:

For electric BrewEasy™ Compact installations, place the kettle on stable, level surface such as the KettleKart™.

For gas BrewEasy™ Compact installations, place the kettle on the burner. Be sure to read the manual for the burner and 

follow any setup instructions it may have. 

IMPORTANT:

 If you are using the Blichmann HellFire™ Burner, it comes configured for LP operation. For use with 

natural gas, you will need to install a natural gas conversion kit. 

Step Two:

Next, install the dip tube and drain valve on the front of your kettle per the diagram below.

Rotating 1.5” G2 Linear Flow Valve

 - Install the rotating valve as shown below. During operation, loosen tri-clamp and rotate 

the dip tube to draw from a higher point above any hops or trub. 

 #

Description

Item #

1

1.5” Clamp

BE-000633-00

2

1.5” Gasket

BE-000868-00

3

Dip Tube O-ring

BE-500386-00

4

Rotating Dip Tube

BE-001686-02

5

1.5” Gasket

BE-000868-00

6

1.5” Clamp

BE-000633-00

7

G2 Tri-Clamp Valve

BE-002055-00

1

2

3

4

5

6

7

The following steps contain assembly procedures for optional accessories that 

may not pertain your system.

Step Three:

If you purchased your system with a controller, install the temperature probe into the tri-clamp adapter cap and install 

on the back-left tri-clamp port as shown in the exploded view below.

 

If you purchased your system without a controller, install the included Brewmometer™ in the 1/2” hole in the front of 

the kettle.

TEMPERATURE SENSOR ASSEMBLY

Number

  Part Number

  Description

1

BE-000882-01

Sanitary Nut

2

BE-000882-01

Sanitary Nut Inner Seal

3

BE-000882-01

Sanitary Nut Outer Seal

4

BE-000013-00

Bulkhead O-ring -113

5

BE-001474-00

Weldless Captive Bulkhead

6

BE-001511-00

Captive Nut O-ring 

7

BE-001475-00

Captive Nut

8

BE-001500-00

Temperature Sensor Probe

1

2

3

Kettle Wall 

with ½” Hole

4 5

6 7

8

To  Temperature 

Probe Port

Inside Kettle

Outside Kettle

COMPLETE TEMPERATURE SENSOR ASSEMBLY

CAUTION:

 

  • Do not pull sensor by cord, pull by stainless sheath only. 

  • Do not remove sensor when kettle is full of liquid without 

    optional thermowell.

Summary of Contents for BrewEasy Compact TC

Page 1: ...ntact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Important should specifically be followed to ensure satisfactory results with the product WARNING CAUTION IMPORTANT IMPORTANTINFORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION Brewing has inherent hazards and requires care focus and a mindset of safety ...

Page 2: ...ander 120V Electric 120V BrewCommander 1 Comes with 120V selection aBrewCommander Gas Gas BrewCommander 1 Optional with gas selection BMA 002F A Brewmometer F 1 Optional with gas selection Recirculation Kit Parts BE 001996 00 Sparge Tube Kit 1 BE 500004 00 Sparge Tube Port Bulkhead 1 BE 000067 00 Retaining O ring 2 KTL 010 00 Retaining Washer 2 BE 000623 01 Wort Flow Meter 1 BE 000359 00 Silicone ...

Page 3: ...386 00 4 Rotating DipTube BE 001686 02 5 1 5 Gasket BE 000868 00 6 1 5 Clamp BE 000633 00 7 G2Tri ClampValve BE 002055 00 1 2 3 4 5 6 7 The following steps contain assembly procedures for optional accessories that may not pertain your system Step Three If you purchased your system with a controller install the temperature probe into the tri clamp adapter cap and install on the back left tri clamp ...

Page 4: ...ht barb QuickConnectors go on the hose that attaches to the drain valve and the pump inlet TIP On straight QuickConnectors leave approximately 1 8 of space between the QuickConnector nut and silicone hose before tightening the plastic clamp TIP Install the QuickConnectors is such a way that minimizes the potential for kinks that can restrict flow TIP Do not mount the pump higher than the standard ...

Page 5: ...nto the two smaller holes on the back right side of your kettle The threaded ends should point outward and will be used to connect the power cable to the BoilCoil Slide the rectangular metal frame onto the two protruding ends and using a 7 8 socket wrench tighten the nuts onto the threads of the BoilCoil Plug the power cable into the BoilCoil and connect the other end to the BrewCommander Step Sev...

Page 6: ...ded 10 minutes turn the pump on and allow the BrewEasy to continuous ly recirculate the wort for the duration of the mashing period Set the flow of the pump to 0 75 gallons per minute and monitor this flow by checking the flow meter throughout the mash If desired after starch conversion you can heat the mash to the desired mash out temperature using the same method described in the Mashing section...

Page 7: ...eading John Palmer s book How to Brew published by the Brewers Association before your first batch This manual is not intended to be a complete all grain brewing text IMPORTANT The quality of your finished beer will be directly related to the quality of your brewing water If you have especially hard water in your area it is strongly recommended that you dilute your tap water with distilled or reve...

Page 8: ...nty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited warranty 2 Blichm...

Reviews: