G5 Weighing Instrument
2-5
ControlNet Module
ControlNet module front view
(1) Network Status LED A.
(2) Module Status LED.
(3) Network Status LED B.
(4) ControlNet connector A.
(5) ControlNet connector B.
Network Status LED A/B
LED
State
Indication
LED A and B Off
Not online / No power
Flashing Red (1 Hz)
Incorrect node configuration, duplicate MAC ID
etc.
Alternating Red/Green Self-test of bus controller
Red
Fatal event or faulty unit
LED A or B
Off
Channel is disabled
Alternating Red/Green Invalid link configuration
Flashing Green (1 Hz) Temporary errors (node will self-correct) or
node is not configured to go online
Green
Normal operation
Flashing Red (1 Hz)
Media fault or no other nodes on the network
Status LED
State
Indication
Off
No power
Green
Operating in normal condition, controlled by a Scanner in
run state
Flashing Green (1 Hz)
The module has not been configuration or Scanner in idle
state
Red
Unrecoverable fault(s), EXCEPTION, fatal event
Flashing Red (1 Hz)
Recoverable fault(s), MAC ID has been changed after
initialization etc.
ControlNet connectors
These connectors provide ControlNet connectivity. If redundancy is wanted both
connectors should be used. Otherwise either connector can be used.
A
B
ControlNet
B
(1)
(2)
(3)
(4)
(5)