1
INSTALLATION - BASICS
Disconnect the installation supply voltage before installing the controller.
Remember that any mounting works should be carried out when the mains
voltage is disconnected (switch off the mains fuse or disconnect the power
cord from the mains socket).
The controller should be installed in a place protected against accidential
destroyment, eg. screwed to the fence pole or inside the enclosure of the
controlled device. Remember that metallic elements (wires, housing parts)
have a negative influence on the range of the device, and consequently the
comfort of use. It is recommended that the device be mounted in a stable and
fixed position with the antenna upside. When installing the device outside of
dry rooms, pay special attention to provide tightness of the rubber cable
glands.
GENERAL CONNECTION DIAGRAM:
CONNECTION DIAGRAM TO TIPICAL CONTROL PANEL:
gate controller board
AC/DC
power inputs
input 2
input 1
output 2 -
output 2 +
output 1 -
output 1 +
common
+
24 V DC for
external accessory
FCO/SWO/FA open possition input
FCC/SWC/FC close possition input
STOP N/C external button
common for external buttons
P. P. N/O external button
common for inputs
control with μWiFi technology
from any place in the World
Apply the safety systems described in the PN-EN 13241 standard
defining the safety requirements and operational requirements
for gates and barriers.
SAFETY RULES
Connect only in accordance with the diagram presented in the
manual. Improper connections may be dangerous, it can damage
the controller, and loss of the warranty.
Connecting the device to a power supply that does not meet the
quality requirements specified in EN 50081-1, EN 50082-1, UL508,
EN 60950 will invalidate the warranty.
DANGER! Risk of electric shock! Even with the device turned off,
the outputs may be live. All assembly work should be ALWAYS
performed with the disconnected power circuit.
110 / 230V
12-24V
power
supply
AC/DC
power inputs
input 2
input 1
output 2 -
output 2 +
output 1 -
output 1 +
common
ex
ter
nal position sensors
open
close
common for inputs
P. P. input
STOP N/C input
gate controller board
DIAGRAM CONNECTION EXAMPLE OF REEL SWITCH FOR SECTIONAL GARAGE DOORS AND SLIDING GATE
- showed at the end of the user guide
GARAGE, SLIDING AND SWING GATES AND DOOR CONTROLLER WITH AN EXTERNAL ANTENNA