Page 1: ...nd Stylish Keep instructions in a safe place for future reference DO NOT DISCARD THESE INSTRUCTIONS Pecan Engineering Pty Limited proudly supports the activities of Landcare Australia through its membership of the AHHA B600 B900 B605 B905 ...

Page 2: ...ZS4013 WARNING DO NOT USE FLAMMABLE LIQUIDSOR AEROSOLS TO START OR REKINDLE THEFIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHENIT IS OPERATING WARNING DO NOT STORE FUEL WITHINHEATER INSTALLATION CLEARANCES WARNING WHEN OPERATING THIS APPLIANCE ASAN OPEN FIRE USE A FIRE SCREEN WARNING OPEN AIR CONTROL AND DAMPERWHEN FITTED BEFORE OPENING FIRINGDOOR CAUTIO...

Page 3: ... frequencies in the home such as wireless internet or child monitor refer to 11 Change Fan Controller Frequency in the Maintenance Servicing section for details on changing the frequency First few times the appliance is lit it will give off some odorous fumes This is caused by the paint curing Do not touch the paint work while it is curing otherwise it can leave a permanent mark on the appliance O...

Page 4: ... the air slide 4 5mm The air slide can be adjusted to any position so desired depending on wanted heat output versus burn time Fan may be turned to low speed setting or off if the heater is putting out sufficient heat without the fan on Reload with more wood 1 Open air slide before opening door 2 Rake break up any existing coals 3 Load the wood with the length orientated front to back 4 Better res...

Page 5: ...k inside of flue prior to each season for any build up of creosote wood tar To do this o First remove the baffle refer to 2 Replacement of Baffle under Maintenance Servicing section o Using a small mirror and torch hold the mirror on an angle below the flue with the torch shining at it and look for black creosote build up If only a fine black powdery layer then that is normal but if built up layer...

Page 6: ...ught Contact the installer should this happen Trouble starting the fire If all ash has been removed from the firebox then it can upset the supply of air to the base of the fire It can aid the fire by retaining some ash when cleaning out the firebox The purpose of the firebricks in the appliance is to increase thermal mass and to guarantee the longevity of the steel firebox Over time the firebricks...

Page 7: ...e rod Over time the screws securing the door hinge plate to the heater may loosen resulting in the door dropping i e visually appears on slight angle and no longer 100 horizontal This can result in a poor door seal and unnecessary amounts of oxygen entering the firebox and wood burning too quickly To fix this and reposition the door 1 With the supplied Allen key loosen the two screws on the hinge ...

Page 8: ...x screws 6 Dispose of the old glass in a responsible manner This task may be easier with the door removed from the appliance and laid horizontally on a work bench 1 Remove any old seal from the door 2 Clean out the groove in the door that the seal was bedded in using a flat end screw driver or equivalent 3 Run a thin bead of clear roof and gutter silicone along the groove 4 Starting at one end pre...

Page 9: ... To access the remote control receiver B600 B900 Models located in the base unit in the rear panel on the left hand side removed via two screws with a M6 Allen key B605 B905 located underneath at the rear of the base unit in a steel cabinet that can be removed via two screws with a M6 Allen key Fan Controller Remove the battery cover and batteries With a small screwdriver or equivalent change the ...