Blaze ASV-2 Operating Manual
Page 17
7 Specifications
Operating Temperature Range
-10ºC to +55ºC (14ºF to 131ºF)
Storage Temperature Range
-20ºC to 80ºC (-4ºF to 176ºF)
Humidity
<85% non-condensing
Power Supply
10 to 30Vdc
Current Consumption
Approx. 125mA @ 12V (backlight highest setting), 50mA @12V (backlight
lowest setting)
Display
2.6” 320x240 IPS color LCD display
Minimum 600cd/m2 brightness
Sunlight readable with anti-glare coating
LED Backlight can be set to automatic or can be manually adjusted
Alarm Output
Open collector transistor switch to ground
Maximum rating 0.25A
Dimensions
see Blaze series dimensional drawing
Enclosure
3 1/8” (80mm) ABS, black in color, front or rear mounting. Flame retardant.
Weight
Approx. 160 grams (Instrument excluding cables)
Non-volatile memory storage
100000 write cycles
Altitude sensor ADC resolution
24 bit
Altimeter range
-1500ft to 35 000ft (-457m to 10668m)
Altitude units
ft or m
Baro Correction Range (inHg)
28.00 to 31.00 “Hg
Baro Correction Range (mB)
946 to 1050 mb
Pressure units
“Hg or mb
VSI range
+-20ft/min to +-10000ft/min
VSI units
ft/min or m/s
Airspeed ADC resolution
ASV-2 Version 1: 12 bit
ASV-2 Version 2: 24 bit
ASV-2HS: 13.5bit
Airspeed range
ASV-2 Version 1: 20mph to 250mph
ASV-2 Version 2: 20mph to 350mph
ASV-2HS (High Speed version): 20mph to 320mph
Airspeed resolution
1 mph
Measurement accuracy
+/- 2mph
Serial Port
RS232 voltage levels
Calibration interval
1 Year
As with any instrument, regular zeroing is suggested to achieve maximum performance.
8 Operating the alarms
The alarm output can be used to switch an external alarm indicator. The external alarm switch is an open collector
transistor switch to ground with a maximum rating of 0.25A DC. It is possible to wire the alarm contacts of several
Stratomaster instruments in parallel should this be desired. To avoid false activation of the alarms, the alarm function is
only active 10 seconds after the instrument has powered up.
9 Firmware Upgrading
The ASV-2 can be upgraded in the field by connecting the RS232 port to a PC and running the firmware update program.
Note that only the RS232 port can be used to upgrade the firmware.
Please see the Blaze firmware upgrading document for more information.