G:\InDATA\manuals\OM-PE E V1.03
December 6, 2012
Page 13
PRINCESS PE 1006
INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for PE1006 and PEJ1006
Residential Installations
A
B
C
D
E
F
J
Roof exit, parallel and corner. No fan kit required.
16”
410mm
9”
230mm
26.5”
675mm
16” *
410mm
14”
360mm
24.75” *
629mm
72”
Roof exit, reduced side. Use side shields.
10”
254mm
9”
230mm
20.5”
520mm
16”
410mm
72”
Roof exit, reduced corner. Use side shields and either fan kit or rear
shield.
6”
153mm
16.75”
425mm
72”
Roof exit, close clearance. Use side shields, and either fan kit or
rear shield.
10”
254mm
6”
153mm
20.5”
520mm
13”
330mm
72”
Wall exit, parallel and corner. No fan kit required.
16”
410mm
9”
230mm
26.5”
675mm
18” *
460mm
14”
360mm
24.75” *
629mm
72” *
Wall exit, reduced side. Use side shields.
10”
254mm
9”
230mm
20.5”
520mm
18”
460mm
72”
Wall exit, reduced corner. Use side shields and either fan kit or rear
shield.
7”
180mm
17.75”
451mm
72”
Alcove, roof exit. Use side shields, and either fan kit or rear shield.
10”
254mm
6”
153mm
20.5”
520mm
13”
330mm
72”
Mobile Home Installation
Roof exit, parallel and corner. Use side shields, either fan kit or rear
shield and outside air kit.
10”
254mm
6”
153mm
20.5”
520mm
13”
330mm
6”
153mm
16.75”
425mm
72”
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Alcove Dimensional Requirements:
Minimum Width 47”, Maximum Depth 48”, Minimum Height above Stove Top, 49”
G = 2.5” (102mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
(If K=18”, J=79.375” (2134mm) Minimum)
This stove must be installed in compliance with all local codes and regulations.