OM-BRII90 E V1.03 wo739
July 14, 2015
Page 18
BRII/90
INSTALLATION INSTRUCTIONS cont.
OPTIONAL ACCESSORIES
Outside air kit, side shields, and rear shield are optional accessories, but are required for the
following installations:
MOBILE HOME INSTALLATION — Requires outside air kit, side shields, and rear shield.
RESIDENTIAL ALCOVE — Requires outside air kit, side shields, and rear shield.
REAR SHIELD KIT (ZRSBRII)
REQUIRED FOR:
MOBILE HOME, any installation
RESIDENTIAL
ALCOVE
INSTALLATION : Th
e rear shield goes across the back of the stove. Remove the four 1/4” x 1/2”
hex bolts. Place the rear shield into position so that the notch on the shield wraps the lip on the
stove top. Insert and tighten the four 1/4” X 2-1/2" hex bolts provided.
FAN KIT (P/N Z1514)
Includes ZRSBRII rear shield
NOTE: Fan kit should be installed before the stove is placed into position
INSTALLATION: See instructions included with fan kit.
ELECTRICAL CONNECTION:
Your Blaze King fan kit is equipped with a three-prong (grounded) plug to decrease shock hazard.
THIS PLUG SHOULD BE INSERTED DIRECTLY INTO A PROPERLY-GROUNDED, THREE-
HOLE RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS
PLUG. Do not route the power cord in front or under the stove.
OUTSIDE AIR KIT (P/N Z1526)
REQUIRED FOR:
MOBILE HOME (any installation)
Th
e outside air inlet hose is a fl exible tube to bring outside air for combustion into the stove from
outside the residence, through the wall or up through the fl oor. Th
e fl exible tube will allow some
adjustment over or around fl oor joists or plumbing.
DO NOT CHANGE THE STRUCTURAL
INTEGRITY OF THE FLOOR
. Th
is air hose must be kept open at all times to provide outside air
for combustion.
INSTALLATION
See instructions included with the outside air kit. Tools needed: 1/4" or 3/8" drill motor, saber
saw, saber saw wood & metal blades, 5/16" nut driver or wrench, 7/16" wrench, Small tube of hi-
heat silicone.