14
ELECTRICAL CONNECTION
• This appliance should only be installed and connected to the electrical system by a qualified
electrician.
• Protection against live parts must be ensured after installation.
• The required connection data can be found on the labels on the hob casing near the connection
box.
• The connection to the mains must be made via an earthed plug or via an all-pole separator with
a contact opening of at least 3 mm.
• The electric circuit must be separated from the mains by means of suitable devices, e.g: circuit
breakers, fuses or contactors.
• If the appliance is not equipped with an accessible plug, separators must be installed in the
system in accordance with the installation instructions.
• The input cable must be laid so that it does not touch any of the hot parts of the hob.
Caution!
This appliance may only be connected to a mains supply with 230 V/400 V ~ 50/60 Hz.
Always connect the earth cable.
Please observe the wiring diagram.
Mains
Connection
Cable diameter
Cable
Protection
class
230V~50/60Hz
1 phase + N
3 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneity factor according to the standard EN 60
335-2-6