Where  a  flexible  hose  assembly  is  used,  ensure  it  is 
approved to AS/NZS 1869, Class B. Any hose assembly 
used  must  be  restrained  from  accidental  contact  with 
the flue outlet of an under bench oven. 
This hose assembly shall be suitable for connection to a 
fixed consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the floor 
and in the region outside the width of the appliance to a 
distance of 250 mm. 

After connecting to gas, check for leaks using soapy 
solution, never a naked flame.  

Inlet connection region for flexible hose

Gas Connection 

Install in accordance with relevant gas standards and/or codes of 
practice applicable.  
Connect the elbow fitting to the appliance gas manifold 
connection, and check that seals between the elbow and 
manifold connection are in place and in good condition.  

For Natural gas: connect the natural gas appliance
regulator (pictured

 

opposite) with integral test point using

approved gas thread tape or

 

compound to the elbow

fitting.

For Universal LPG: connect the brass test point adaptor
(pictured opposite)

 

using approved gas thread tape or

compound to the elbow fitting.

Ensure the supply connection point, test point and natural gas 
regulator  adjustment  screw  (for  Natural  gas  installation)  are 
accessible  for  testing  and/or  adjustment  with  the  hotplate  in 
the installed position.  

20

Flexible Hose: If installing with a hose assembly, it must comply with AS/NZS

1869,10mmID,class B or D,no more than 

 m long and installed in 

accordance with AS/NZS 5601.1.

Ensure that the hose does not contact the hot surfaces of the 

hotplate,oven,dishwasher or any other appliance that may be installed 

underneath or next to the hotplate.The hose should not be subjected to abrasion, 

kinking or permanent deformation and should be able to be inspected along its 

entire length with the cooktop in the installed position. Unions compatible with 

the hose fittings must be used and all connections tested for gas leaks.The 

supply connection point shall be accessible with the appliance installed.

WARNING: Ensure that the hose assembly is restrained from accidental contact 

with the flue outlet of an underbench oven.

G

as 

C

onnection

1.2

Summary of Contents for 5GB61150AU

Page 1: ...Gas hobs Instruction manual 5GB61150AU 5GB61151AU 5GB62191AU...

Page 2: ...facturer shall not be responsible for any damages to persons or property caused by incorrect installation or use of the appliance The appliance has been certified for use in countries other than those...

Page 3: ...ice 8 Environmental Information Description of the appliance How to Use the appliance Safety and Energy saving advice Cleaning and Maintenance Technical instructions 6 16 17 18 21 15 13 12 23 2 5 4 3...

Page 4: ...1 1000 of the gas is in the air The following marks are used in the Instruction Manual as follows 3 If gas seems to leak take the actions as follow Neglect of this mark may result in severe personal i...

Page 5: ...QRW GDPDJHG DQG WKDW WKH connection cord is in perfect condition Otherwise contact the dealer before installing the appliance 7KH DGMDFHQW IXUQLWXUH DQG DOO PDWHULDOV XVHG LQ WKH LQVWDOODWLRQ PXVW EH...

Page 6: ...VLJQHG WR EH RSHUDWHG E DGXOWV KLOGUHQ FDQ DOVR LQMXUH WKHPVHOYHV E SXOOLQJ SDQV RU SRWV RII WKH DSSOLDQFH 7KLV DSSOLDQFH LV QRW LQWHQGHG IRU XVH E FKLOGUHQ RU RWKHU SHUVRQV ZKRVH SK VLFDO VHQVRU RU P...

Page 7: ...l is not designed to operate from an external timer or separate remote control system 6 2QO XVH WKH DSSOLDQFH IRU SUHSDULQJ food LQ contact with water Do not operate this appliance with wet hands R QR...

Page 8: ...HDW XS DQ HPSW is made of glass cracked switch off the appliance to avoid defeat electrocution 7R PLQLPLVH WKH SRVVLELOLW RI EXUQV LJQLWLRQ RI DPPDEOH PDWHULDOV DQG VSLOODJH WXUQ FRRNZDUH KDQGOHV WRZD...

Page 9: ...QJ WR FOHDQ WKH DSSOLDQFH LW VKRXOG EH GLVFRQQHFWHG IURP WKH PDLQV RX VKRXOG QRW XVH D VWHDP MHW RU DQ RWKHU KLJK SUHVVXUH FOHDQLQJ HTXLSPHQW WR IWHU LQVWDOODWLRQ SOHDVH GLVSRVH RI WKH SDFNDJLQJ with...

Page 10: ...nition device Gas Connection Electric supply Burner Feature Dimension W D H Top Plate Steel 2W 30 4MJ h 5GB61150AU 5GB61151AU Qn 590 510 90 Continuous Ignition Type G1 2 thread 220 240Vac 50Hz 60Hz Tr...

Page 11: ...liance is fitted with a flame failure safety device on each burner which is designed to stop the flow of gas to the burner head in the event of the flame going out Injector The minimum setting is at t...

Page 12: ...e o o After this 15 second interval to regulate the flame you should continue turning the control knob anti clockwise until the flame is at a suitable level The operating position MUST be at a positio...

Page 13: ...y on top of the burner Do not place anything eg flame tamer asbestos mat between pan and pan support as serious damage to the appliance may result Do not use excessive weight and do not hit the cookto...

Page 14: ...FOHDQLQJ 7KRURXJKO UHPRYH VDOW IRRGV RU OLTXLGV IURP WKH KRE DV VRRQ DV SRVVLEOH WR DYRLG the risk of corrosion 6WDLQOHVV VWHHO SDUWV RI WKH DSSOLDQFH PD EHFRPH GLVFRORXUHG RYHU WLPH 7KLV LV normal be...

Page 15: ...op plate 6RDN WKHP LQ KRW ZDWHU DQG D OLWWOH detergent or washing up liqui IWHU FOHDQLQJ DQG ZDVKLQJ WKHP ZLSH DQG GU WKHP FDUHIXOO 0DNH VXUH WKDW WKH DPH KROHV DUH FOHDQ DQG FRPSOHWHO GU LSH WKH HG S...

Page 16: ...GQ W EH EHQW RU EORFNHG E DQ RWKHU DSSOLDQFHV KHFN WKH GLPHQVLRQV RI WKH DSSOLDQFH DV ZHOO DV WKH GLPHQVLRQV RI WKH JDS WR EH FXW LQ WKH NLWFKHQ XQLW 7KH SDQHOV ORFDWHG DERYH WKH ZRUN VXUIDFH GLUHFWO...

Page 17: ...of the hob 50 mm clearance around the appliance and between the hob surface and any combustible materials 45 mm 60 You must have a gap of at least 25 mm and at most 74 mm between the underneath of the...

Page 18: ...our worktop Then fully tighten the screws C to secure the hob into position A SEALING STRIP C SCREW B BRACKET 17 Remove the pan supports the burner lid and flame spreader and carefully turn the applia...

Page 19: ...shown below Some are optional Replacement of gas type fitting Tool Open end wrench Steps for operation A Disassemble with a wrench the gas type fittings from main gas tube When you disassemble assemb...

Page 20: ...hole length of the connection hose must be possible and the gas hose must be replaced before its use before the end of service life indicated on the hose Before Leaving Check all connections for gas l...

Page 21: ...itting For Universal LPG connect the brass test point adaptor pictured opposite using approved gas thread tape or compound to the elbow fitting Ensure the supply connection point test point and natura...

Page 22: ...on 21 Wok burner Rapid burner Semi rapid Auxiliary 10 8MJ h 6 3MJ h 0 68 0 58 1 15 0 93 13 5MJ h 1 72 Heat input and orifice size marked mm Gas type pressure 2 75kPa Natural Gas 1 0kPa Universal LP Ga...

Page 23: ...VW EH FRQQHFWHG WR WKH WHUPLQDO ZKLFK LV PDUNHG ZLWK WKH OHWWHU RU E WKH HDUWK V PERO 5 When the power cord is damaged it must be replaced by the manufacturer to produce customer service agent or simi...

Page 24: ...HPRYH WKH SUHYLRXV VHWWLQJ 9 PDUN LQ WKH HYHQW RI D PDOIXQFWLRQ FKDQJH WKH ZKROH WDS IXOO RSHUDWLRQDO WHVW DQG D WHVW IRU SRVVLEOH OHDNDJHV PXVW EH IWHU FRPSOHWLQJ FRQYHUVLRQ GHWHFWRU Change the injec...

Page 25: ...The burners are wet Dry the burners lids carefully The holes in the flame spreader are clogged Clean the flame spreader The burner lid is badly assembled Assemble the burner lid correctly The flame s...

Page 26: ......

Page 27: ......

Page 28: ...punkt einbaugeraete com 00 800 32 289 000 www blaupunkt einbaugeraete com Luxemburg Luxembourg service LU blaupunkt einbaugeraete com Schweiz Switzerland service CH blaupunkt einbaugeraete com Italien...

Reviews: