VENTO A50 / A50-1 / A50 S / A50-1 S

We are happy to offer your attention a new high-quality single-room 

reversible unit with heat and humidity recovery 

VENTO A50 / VENTO A50-1

The solid team of high-qualified professionals with many years of working 

experience, technological innovations in design and production, high-

quality components and materials from the top worldwide producers have 

become the precondition for the best energy saving unit in its class.

INTRODUCTION

The present operation manual contains technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 

warnings for safe and correct operation of the unit.

GENERAL

The single-room unit is designed for efficient energy saving supply and 

exhaust ventilation of flats, houses, cottages and other small premises. 

The heat recovery technology is used to minimize ventilation heat losses.

The unit is equipped with a high-tech ceramic heat accumulator 

(regenerator) that provides utilization of extract air heat energy for warming 

up of filtered supply air flow.  The heat regeneration efficiency is up to 91%.

The unit is designed for indoor application with the ambient temperature 

ranging from -20 °C up to +50 °C and relative humidity up to 80%.

The unit is designed for external through-the-wall installation. 

The unit is designed for continuous operation always connected to power 

mains. 

The unit is allowed for operation only after final mounting, that includes 

installation of protecting devices in compliance with DIN EN ISO 13875 (DIN 

EN OSI 12100) as well as other construction safety equipment. 

The unit design is regularly improved, so some models may slightly differ 

from those ones described in this operation manual.

SAFETY RULES

The unit complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

All operations related to the electrical connection of the unit, like servicing 

and repair works are allowed only after the disconnection from power mains.

All mounting and servicing operations are allowed for duly qualified 

electricians with valid electrical work permit for electric operations at the 

units up to 1000 V after careful study of the present operation manual. 

The unit must be grounded! 

Please follow the safety regulations and working instructions (DIN EN 50 

110, IEC 364).

Make sure the impeller and the casing are not damaged before 

connecting the unit to power mains. The casing internals must be free of any 

foreign objects which can damage the impeller blades.

Disconnect the unit from power mains prior to any operations related to 

the unit servicing and repair works.

Misuse of the unit or any unauthorized modification are not allowed. 

The unit is designed for connection to AC single-phase power mains, see  

the Technical Data. The unit is rated for permanent operation during non-

stop power supply. 

Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.

The transported air must not contain any dust or other solid impurities, 

sticky substances or fibrous materials. 

The unit is not designed for use in an inflammable and explosive medium. 

Do not close or block the unit intake or exhaust vent not to disturb the 

normal  air passage. 

Do not sit on the unit and do not put objects on the unit.

In case of unusual sounds, smoke disconnect the unit from power supply 

and contact the service centre.

Follow the manual guidelines to ensure trouble-free operation and long 

service life of the product.

Hazardous parts access and water ingress protection standard IP24.

STORAGE AND TRANSPORTATION RULES

Transportation of the unit is allowed by any vehicle provided the unit is 

transported in the original package and is protected against weather and 

mechanical damages. 

Use hoist machinery for handling and transportation to prevent possible 

mechanical damages of the unit. Fulfil the requirements for transportation of 

the specified cargo type during cargo-handling operations. 

Store the unit in a dry and cool place in the original packing.

The storage environment must not be subjected to any aggressive and/

or chemical evaporations, admixtures, foreign objects that may provoke 

corrosion and damage connection tightness. 

Store the unit in an environment with minimized risk of mechanical 

damages, temperature and humidity fluctuations. 

Do not expose the unit to the temperatures below +10°C and above +40 °C .

Connection of the unit to power mains is allowed after the unit has been 

kept indoor for minimum two hours.

MANUFACTURER’S WARRANTY

The product complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

We hereby declare that the following product complies with the essential 

protection requirements of Electromagnetic Council Directive 2004/108/

EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and 

CE-marking Directive 93/68/EEC on the approximation of the laws of the 

Member States relating to electromagnetic compatibility. 

The manufacturer hereby warrants normal operation of the unit over 

the period of 2 years from the retail sale date provided observance of the 

installation and operation regulations.

In case of failure due to manufacturing fault during the warranty period 

the consumer has the right to exchange it.

If case of no confirmation of the sale date, the warranty period shall be 

calculated from the manufacturing date.

The replacement is offered by the Seller. 

The manufacturer shall not be liable for any damage resulting from any 

misuse of or gross mechanical interference with the unit.

Fulfil the operation manual requirements to ensure a trouble-free and 

long service life of the unit.

 

                 WARNING

Do not dispose in domestic waste. 
The unit contains in part material that can be 

recycled and in part substances that should not end up 
as domestic waste.

Dispose of the unit once it has reached the end of 

its working life according to the regulations valid where 
you are. 

 

                  ATTENTION

The product is not allowed for use by children and persons with reduced 

physical, mental or sensory capacities, without proper practical experience 
or expertise, unless they are controlled or instructed on the product opera-
tion by the person(s) responsible for their safety. Supervise the children and 
do not let them play with the product. 

Summary of Contents for VENTO A50

Page 1: ...OPERATION MANUAL VENTO A50 VENTO A50 1 VENTO A50 S VENTO A50 1 S Single room reversible unit with heat and humidity recovery ...

Page 2: ...3 Transportation and storage rules 3 Manufacturer s warranty 3 Design and operating logic 4 Modifications and options 5 Delivery set 5 Technical data 6 Mounting 6 Connection and control 9 Maintenance 14 Troubleshooting 15 Acceptance certificate 16 Connection certificate 16 Warranty card 16 CONTENTS ...

Page 3: ...fting The maximum permitted pressure difference per living units is 4 Pa The transported air must not contain any dust or other solid impurities sticky substances or fibrous materials The unit is not designed for use in an inflammable and explosive medium Do not close or block the unit intake or exhaust vent not to disturb the normal air passage Do not sit on the unit and do not put objects on the...

Page 4: ...e unit minimum or maximum speed ventilation mode air supply or air extract reversible operation mode with heat regeneration The external control and power unit SEA T12 or the control panel SEA is used for operation mode control The delivery set of the unitsVENTO A50 Pro A50 1 Pro A50 S Pro A50 1 S Pro includes the control and power unit SEA T12 consisting of the control panel SEA and the 12W trans...

Page 5: ...h the control panel and the control unit SEA T12 VENTO A50 S Pro VENTO A50 1 S Pro The unit for the wall thickness from 120 up to 420 mm Compatible with the control panel and the control unit SEA T12 DELIVERY SET Unit 1 item Fixing set 1 item SEA T12 control and power unit for Pro models 1 item Cable Unitronic LIYY UL CSA 5xAWG 7 5x0 25 3 m long 1 item Operation manual 1 item Packing box 1 item AT...

Page 6: ...ng foam MOUNTING WARNING Read the operation manual prior to any electric installations Connection of the unit to power mains is allowed by qualified professionals The unit is designed for through the wall mounting in the building outer wall Mounting sequence 1 Prepare a round core hole through the outer wall The size is shown in the figure 7 While mounting several connected in series units provide...

Page 7: ...on unit mm 195 Ø6 4 holes 150 196 170 7 Mark the fastening holes for the outer ventilation hood Fig 11a for the modelsVENTO A50 A50 1 Fig 11b for the modelsVENTO A50 S A50 1 S Drill 40 mm holes for the dowels 6x40 Fig 11а Fig 11b 193 5 Ø6 4 holes 246 4 220 Ø6 4 holes 220 8 Insert the dowels 6x40 from the delivery set into the holes 9 Disassemble the outer ventilation hood to enable access to the f...

Page 8: ...11 Install the upper part of the outer ventilation hood Fig 14a for the modelVENTO A50 A50 1 Fig 14b for the model VENTO A50 S A50 1 S Fig 13а Fig 14а Fig 13b Fig 14b 12 Install the control panel SEA T12 with a power unit inside a prepared hole in the wall see fig 15 The control panel mounting place must be inaccessible for children During selection of the control panel mounting place consider the...

Page 9: ...ontrol and power unit SEA T12 consists of a control panel and a 12 W power transformer fig 16 In case of the control panel SEA either power transformer AT 12 or AT 40 are used and are available upon separate order The unit is rated for connection to single phase alternating current power mains 230 V 50 Hz or 120 V 60 Hz depending on the used transformer type Separate power supply must be provided ...

Page 10: ...it board to ensure correct and quick electric installation The control panel SEA is used to set one of four operation mode of the unit fig 17 1 Ventilationmode airextract airsupply atthefirstspeedwithairflow26m3 h 2 Ventilation mode air extract air supply at the second speed with air capacity 53 m3 h 3 Reversible regeneration operation at the first speed with air flow 26 m3 h The unit changes air ...

Page 11: ...ket connectors of the connecting cable supplied with the unit are marked 1 to 5 and must be connected to the controller socket connectors marked 11 15 for outputs or 21 25 for inputs Cable channel B 1 Vento A50 Cable channel A 1 Vento A50 Cable channel B N Vento A50 Cable channel A N Vento A50 SEA control panel 120 V or 230 V 120 В или 230 В 120 V or 230 V 120 V or 230 V 120 V or 230 V 120 V or 23...

Page 12: ... connect the 12W transformer wire leads to the contacts A1 35 36 of the controller A1 SEA using the socket connector at the cable K2 The cable is included into delivery set of the 40W transformer model Then connect the first unit A3 No 1 to the contacts A1 11 15 of the controller SEA using the connecting cable supplied with the first unit Connect the second unit A3 No 2 contacts A2 21 25 to the fi...

Page 13: ...wn yellow green white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 y...

Page 14: ... least once in three months To clean the filters flush those under running water or use a vacuum cleaner fig 24 Let the filters dry and install the dry filters inside the air duct Contact a local distributor for the filters stated above in the section Technical data Even regular filter maintenance may not completely prevent the dust ingress into the regenerating unit Clean the regenerator with a v...

Page 15: ...unit Automatic switch tripping during the unit start Short circuit in power grid as a result of short circuit Turn the unit off Contact the seller Low air flow Low set fan speed Set higher speed The filters the fan or the regenerator are soiled Clean or replace the filter Clean the fan and the regenerator For the regenerator and the filter maintenance refer page 15 Noise vibration The impeller is ...

Page 16: ...ng Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date ____________________ Company Name Date Signature The single room reversible unit with heat and humidity recovery VENTO A50 Pro VENTO A50 VENTO A50 1 P...

Page 17: ...________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______...

Page 18: ...________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______...

Page 19: ...________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______...

Page 20: ...www blaubergventilatoren de VENTO A50 v 5 5 06 2014 EN ...

Reviews: