FAN ADJUSTMENT
16
3
SLEEP mode air capacity, m /h
3
24 HOURS mode air capacity (Ø125 / Ø100), m /h
3
QUIET mode air capacity (Ø125 / Ø100), m /h
3
MAXIMAL mode air capacity (Ø125 / Ø100), m /h
humidity extraction mode
turn-on delay timer settings, min
turn-off delay timer settings, min
humidity timer settings, min
Motion sensor (for model SMART IR only)
24 HOURS mode
0
40/33
83/72
97/82
MAXIMAL
0
5
30
off
off
Table 5
FACTORY SETTINGS
CONTROL PANEL
Adjustment of the humidity
extraction mode
Adjustment of the turn-on/
turn-off delay timer
Speed adjustment for the modes
QUIET and MAXIMAL
Adjustment of the turn-on delay timer
Turning motion sensor on/off
Turning 24 HOURS mode on/off
Extra button to control the fan
SMART
SMART IR
23
The fan is adjusted at the factory and is ready for operation. It is a fully serviceable
product that does not require compulsory adjustments. If you want to adjust the fan
according to your needs, please follow the instruction below. In case of need you may
reset to the factory settings.