BLAUBERG ERV H 120 Operation Manual Download Page 9

9

www.blaubergventilatoren.de

HRV/ERV H 120(170)

•  Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range 

from +5 ˚С  (+41 ˚F) to +40 ˚С  (+104 ˚F) and relative humidity up to 70 %.

•  Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation, and sealing deformation.
•  Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
•  Follow the handling requirements applicable for the particular type of cargo.
•  The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical 

damage. The unit can be transported only in the working position.

•  Avoid sharp blows, scratches, or rough handling during loading and unloading.
•  Prior to the initial power-up after transportation at low temperatures allow the unit to warm up at room temperature for at least 3-4 hours.

STORAGE AND TRANSPORTATION RULES

MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the 
product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and CE-marking Directive 
93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 60 months after the retail sale date provided the user's observance of the 
transportation, storage, installation, and operation regulations.
Should any malfunctions occur in the course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user 
is entitled to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work 
specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation. 
The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

•  routine technical maintenance
•  unit installation/dismantling 
•  unit setup
To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment paperwork certifying 
the purchase.
The unit model must comply with the one stated in the user’s manual. 
Contact the Seller for warranty service. 

The manufacturer’s warranty does not apply to the following cases:

•  User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts 

previously dismounted by the user.

•  Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
•  User’s failure to ensure timely technical maintenance of the unit.
•  External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.
•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE 

ANY MAINTENANCE OPERATIONS!

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF 

THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE PURCHASE DATE 

STAMP.

Summary of Contents for ERV H 120

Page 1: ...OPERATION MANUAL EN HRV H 120 ERV H 120 HRV H 170 ERV H 170 HEAT RECOVERY VENTILATOR ...

Page 2: ...rranty 9 The HRV ERV H 120 170 unit is designed for ceiling mounting The HRV ERV H 120 170 is designed for ceiling and wall mounting The unit is designed to save thermal energy by means of heat recovery and is one of the energy saving components used in the buildings and premises The ventilator is a component unit and is not designed for independent operation The unit is designed to provide perman...

Page 3: ...se 1 pce Oil filter 1 pce Packing box 1 pce The unit is designed for indoor installation and operation at the ambient air temperature ranging from 34 F 1 С up to 122 F 50 С Ingress Protection rating IP44 for the unit motors IP 22 for the assembled unit connected to air ducts The unit net weight is 66 lbs 30 kg The unit series designation basic overall and connecting dimensions are shown in fig 1 T...

Page 4: ...RYERS OR SIMILAR EQUIPMENT TO THE VENTILATION SYSTEM DO NOT OPERATE THE UNIT IN THE AIR AND DUST MIXTURE ENVIRONMENT STRUCTURE AND OPERATING LOGIC Fig 2 Unit structure and operating logic The unit has the following operating logic fig 2 Warm stale extract air from the room flows through the air ducts to the unit is purified in the extract filter and is supplied to the heat recovery core and exhaus...

Page 5: ...Frost protection thermostat MOUNTING AND SET UP Fig 3 Unit mounting While mounting the unit provide enough access for the unit maintenance and servicing Mount the unit to ceiling with threaded rods fixed inside the dowels attached to the ceiling or by means of the belts that are rigidly fixed to horizontal plane fig 3 The unit can be installed on mounting supports with adjustable height for connec...

Page 6: ...drain system and provide air heating min 3 1 3 5 2 4 fig 5 Condensate drainage The unit is designed for connection to single phase ac 120 V 60 Hz power mains The unit is equipped with a power cable and a plug and can be connected to any standard grounded outlet The power cable is connected to the terminal X1 by default Connect the unit to power mains through the external automatic switch integrate...

Page 7: ...sition speed switch that enables low speed modes Low as well as Med and Stand by mode which enables total air quality control fig 7 Up to five external control devices may be connected to the terminals 2 11 fig 7 that turn the unit to high speed ventilation in case of activation of any of the control devices Three speed switch Terminals for connection of the remote control panel Fig 7 Unit control...

Page 8: ...te drainage system maintenance once per year applicable only for HRV H 120 170 The drain hose can get clogged with the extracted particles Clean the drain hose is required Check proper functioning of the drain system by pouring some water into the drain pan at the unit bottom Clean the U trap and the drain tubes if required 5 Supply air flow inspection twice per year Leaves and other objects can c...

Page 9: ... replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must comply with the one stat...

Page 10: ...pany Stamp The single room reversible energy regeneration ventilator HRV ERV H 120 170 has been connected to power mains pursuant to the requirements stated in the present user s manual Company Name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all applicable local and national construction elec...

Page 11: ...11 www blaubergventilatoren de HRV ERV H 120 170 ...

Page 12: ...www blaubergventilatoren de HRV ERV_H_120 170 _EN 01 ...

Reviews: