BLAUBERG BLABQUATRO User Manual Download Page 3

3

EN

READ THE USER’S MANUAL CAREFULLY BEFORE PROCEEDING WITH INSTALLATION WORKS.

COMPLIANCE WITH THE MANUAL REQUIREMENTS ENSURES RELIABLE OPERATION AND LONG 

SERVICE LIFE OF THE UNIT.

KEEP THE USER’S MANUAL AVAILABLE AS LONG AS YOU USE THE UNIT. YOU MAY NEED TO  

REREAD THE INFORMATION ON THE PRODUCT SERVICING.

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the 
BLABQUATRO unit  and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should 
be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the 
territory of the country.
The information in this user’s manual is correct at the time of the document’s preparation.
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time 
in order to incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any 
information search system or translated into any language in any form without the prior written permission of the Company.

Summary of Contents for BLABQUATRO

Page 1: ...USER S MANUAL BLABQUATRO AXIAL WALL CEILING FAN EN ...

Page 2: ...2 EN CONTENTS Safety Instructions 4 Delivery set 6 Brief description 6 Operation guidelines 6 Installation and set up 6 Technical maintenance 7 Storage and transportation regulations 7 Warranty 8 ...

Page 3: ...d maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the technic...

Page 4: ...ains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between the circuit breaker contacts on all poles must be not less than 3 mm Check the unit for any visible damages of the impeller and the casing before starting installation The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compressi...

Page 5: ...e efficient air flow Do not sit on the unit and do not put objects on it This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Ensure that the fan is switched off from ...

Page 6: ... unit is rated as a Class II electrical appliance INSTALLATION AND SET UP The fan is designed for wall or ceiling mounting with direct air exhaust to the ventilation shaft or into the round air duct of matching diameter Fig 2 Fan installation sequence step 1 Cut off power supply and make sure electricity has been turned off Fig 5 step 2 Run the power cable to the vent hole Fig 6 step 3 Remove the ...

Page 7: ...a dry closed ventilated premise with temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particula...

Page 8: ...installation reinstallation or transporting the product Additional information Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount...

Page 9: ...STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE FREE OPERATION OF THE UNIT USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP ...

Page 10: ...10 EN a a1 b d e c 1 2 Model Dimensions mm Weight kg a a1 b c d e BLABQUATRO 100 171 151 108 128 100 32 0 56 125 201 178 113 136 125 35 0 73 150 236 207 165 157 150 38 0 9 ...

Page 11: ...11 EN 3 4 ...

Page 12: ...12 EN QF L N 5 6 7 8 9 10 11 12 ...

Page 13: ...13 EN L QF N L N S S L N QF L N L N QF L N Contact of the switch is OPEN Fan runs Contact of the switch is CLOSED Fan does not run 13 BLABQUATRO 100 125 150 BLABQUATRO 100 125 150 S ...

Page 14: ...14 EN QF L N 14 15 16 17 ...

Page 15: ...15 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Page 16: ...Blauberg_Australasia_B174EN 02 www blaubergventilation com au BLABQUATRO BLABQUATRO 100 125 150 ...