www.blaubergventilatoren.de
Solo a35/50/60 S4 Pro r (v.2)
9
The ventilator is rated for connection to single-phase AC 230 V, 50 Hz power mains using a power cable with a plug installed at the factory.
WARNING!
The unit must not be connected through any type of speed regulators – thyristor, autotransformer, frequency, etc.
The ventilator must be connected to the stationary power supply via an integrated switch with a gap between the contacts at all poles
of at least 3 mm.
The unit is equipped with an electric motor, which has two fixed speeds.
Controlling the Solo A35 S4 Pro R ventilator using a pull cord switch
The ventilator is connected to power mains using a cord with a plug with a switch on the wire.
Switching from the first speed to the second is carried out only by a standard pull cord switch.
Speed switch
(speed I-II)
ON/OFF
230 V, 50 Hz
CONNECTION TO POWER MAINS
POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT.
THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN.
THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE
MANUFACTURER’S LABEL.
ALL THE COMPONENTS OF THE UNIT ARE ITS INTEGRAL PARTS.
MAINTAINING THE FACTORY CONFIGURATION AND FORM FACTOR IS ABSOLUTELY
ESSENTIAL FOR THE PROPER AND CONSISTENT FUNCTIONING OF THE UNIT.
ANY UNAUTHORISED ALTERATIONS TO THE UNIT FORM FACTOR OR FAILURE TO ADHERE
TO THE ELECTRICAL CONNECTIONS DIAGRAM SHALL RELIEVE THE MANUFACTURER
FROM LIABILITY FOR ANY RESULTING MALFUNCTIONS AND VOID THE UNIT WARRANTY.