READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES,  

READ THE RELEVANT USER MANUALS.

DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST 

ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. 

AS IT PREVENTS AIR CIRCULATION IN THE ROOM.

To install an external ventilation hood or grille, it is necessary to have access to the external surface of the wall at the place of 

installation.

1. Prepare a round core hole in the outer wall.
The diameter of the hole depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the 
«Technical data» section.

Ø D1

min 300

min 300

min 300

A

A

A-A

 

2. Install the telescopic air duct in the hole in such a way that its sections coincide with the outer and inner surface of the wall. For ease 
of installation, use mounting wedges.
Install the air duct with the minimum slope of 3 mm downwards from the outer wall side.

Fill the gaps between the wall 

and the hole with a 

mounting foam.

Foam wedge

min 3 mm

3. Install the outdoor grille, connecting the power from the solar battery to the fan.

MOUNTING AND SET-UP

Summary of Contents for SHM 100 DK

Page 1: ...Wall ventilator USER S MANUAL EN SHM 100 DK ...

Page 2: ...e territory of the country SAFETY REQUIREMENTS This unit is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit T...

Page 3: ...the unit and any unauthorized modifications are not allowed Do not expose the unit to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ...

Page 4: ...1 pc DELIVERY SET PURPOSE The ventilator is designed to ensure continuous mechanical air exchange in flats cottages hotels cafés and other domestic and public premises Designed for in wall installation In sunny weather the ventilator provides ventilation due to the built in fan which is powered by a solar battery In cloudy weather and at night natural ventilation is created due to the difference i...

Page 5: ...he building Protect the surface of the photocells against possible damage including scratches as this reduces the amount of light that reaches the photocells and therefore the output current The temperature of the transported air should be in the range from 15 С to 40 С The unit is rated as a Class III electrical appliance Ingress protection rating against access to hazardous parts and water ingre...

Page 6: ...scopic PVC air duct is adjustable The outer grille is made of high quality UV resistant ASA plastic The solar panel is attached to the surface of the hood to power the motor DESIGN AND OPERATING PRINCIPLE The solar battery provides autonomous power for the fan motor The fan creates a more intense air exchange than with conventional passive ventilation The electrical parameters of the battery vary ...

Page 7: ...epare a round core hole in the outer wall The diameter of the hole depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the Technical data section Ø D1 min 300 min 300 min 300 A A A A 2 Install the telescopic air duct in the hole in such a way that its sections coincide with the outer and inner surface of the wall For ease of installation use mount...

Page 8: ... FOR THE PROPER AND CONSISTENT FUNCTIONING OF THE UNIT ANY UNAUTHORISED ALTERATIONS TO THE UNIT FORM FACTOR OR FAILURE TO ADHERE TO THE ELECTRICAL CONNECTIONS DIAGRAM SHALL RELIEVE THE MANUFACTURER FROM LIABILITY FOR ANY RESULTING MALFUNCTIONS AND VOID THE UNIT WARRANTY 4 Install the internal grille 5 Adjust the airflow regulator Closed Open 6 Assemble the internal grille ...

Page 9: ...ry is dirty Clean the solar battery Noise vibration The impeller is clogged Clean the impeller Loose screw connection of the unit casing or the outer ventilation hood Tighten the screws of the ventilator or the outer ventilation hood TROUBLESHOOTING STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature...

Page 10: ...the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual...

Page 11: ...RTIFICATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes a...

Page 12: ...www blaubergventilatoren de B227EN 01 ...

Reviews: