Iso-ZS

4

1

2

Overall and connecting dimensions of Iso-ZS fan 

with one intake and one exhaust spigot 

Overall and connecting dimensions of Iso-ZS fan 

with two intake spigots and one exhaust spigot 

251

251

266

306

Iso-ZS 315/2x250 6E

H2

H1

H

B2

L

L1

B

B1

B3

L2

600

500

580

31

H3

313 248

M8

550 171 431

340 176 326 680

510

Iso-ZS 315/2x250 4E

Iso-ZS 315/2x250 4E max

Iso-ZS 315/2x250 6E max

600

650

670

500

530

610

580

635

725

33

38

45

313

313

313

248

248

248

M8

M8

M10

550

610

620

171

188

216

431

465

457

340

450

367

176

186

186

326

346

427

680

735

825

510

570

660

Modell  

Dimensions [mm] 

Weight 

[kg] 

Iso-ZS 250-6E

Iso-ZS 315 6E

Iso-ZS 250-4E

Iso-ZS 315 4E

Iso-ZS 250 6E max

Iso-ZS 315 4E max

Iso-ZS 250 4E max

Iso-ZS 315 6E max

H1

H

B

B1

H2

L

L1

L2

313

313

313

313

M8

M8

M8

M10

600

600

650

670

550

550

610

620

500

340

500

530

610

340

450

367

580

680

510

580

635

725

680

735

825

510

570

660

31

33

38

45

H

L1

L

H1

H2

B

D

D

B1

L2

d

H

L1

L

H1

H2

B2

B3

H3

D1

D1

B

D

B1

L2

d

table 1

21,5

21,5

470

470

435

435

455

455

248

248

M8

M8

400

400

298

298

216

216

570

570

400

400

30,8

30,8

540

540

483

483

503

503

248

248

M8

M8

450

450

340

340

241

241

640

640

470

470

table 2

Modell  

Dimensions [mm] 

Weight 

[kg] 

Summary of Contents for Iso-ZS

Page 1: ...EN Iso ZS User s manual...

Page 2: ...Purpose Delivery set Technical data Safety requirements Fan design TSC module description and functioning Mounting and set up Connection to power mains Wiring diagrams Technical maintenance Storage r...

Page 3: ...us operation The fan requires simple maintenance and is applicable for the transported air temperature from 20 C up to 45 C Hazardous parts access and water ingress protection ratings is IP X4 The del...

Page 4: ...1 465 457 340 450 367 176 186 186 326 346 427 680 735 825 510 570 660 Modell Dimensions mm Weight kg Iso ZS 250 6E Iso ZS 315 6E Iso ZS 250 4E Iso ZS 315 4E Iso ZS 250 6E max Iso ZS 315 4E max Iso ZS...

Page 5: ...Exhaust spigot 5 Terminal box 6 Fan grounding 7 Impeller 8 Mounting nut 9 Speed control knob 10 Temperature control knob 11 Fan operation indicator 12 Thermostat indicator 1 Fan casing 2 Sound insula...

Page 6: ...Iso ZS 6 5 Iso ZS fan mounting and operation example 1xD 3xD 6 General mounting recommendations for Iso ZS fans...

Page 7: ...accomplished either via a terminal block 5 or a power cable with a plug 13 for R modification The fan casing has a slot for connection of the fan grounding 6 The impeller 7 is fixed directly to the m...

Page 8: ...c speed and temperature control module enable fan speed control depending on the air temperature in the air duct Depending on the fan model the return to pre set lower speed has two delay patterns tem...

Page 9: ...e by turning the speed control knob 9 The fan operation indicator 11 lights up as the fan is started If the air temperature increases above the thermostat set point the fan switches to the high speed...

Page 10: ...otation speed is 60 of the maximum speed Set temperature point is 25 C Air duct temperature is 20 C 1 Fan impeller rotation speed is 60 2 Air duct temperature increases reaches 25 C and continues to g...

Page 11: ...and to minimize turbulence induced air pressure losses connect a straight air duct section to the fan spigots on both sides of the fan The minimum straight air duct length is equal to 1 air duct diame...

Page 12: ...le cross section consider the cable type its maximum heating temperature insulation length and installation method The fan requires safe grounding Connect the fan to 230 V 50 Hz power mains through th...

Page 13: ...QF 7 8 9 10 MOUNTING OPTIONS 13 Iso ZS...

Page 14: ...Iso ZS 14 QF 11 12 13 14...

Page 15: ...QF 15 16 17 18 15 Iso ZS...

Page 16: ...QF 19 20 21 22 Iso ZS 16...

Page 17: ...the delivery set Terminal block X1 1 2 3 4 X1 L N QF L 230V 50Hz N PE Recommended trip current of the automatic circuit breaker QF 23 Iso ZS 315 6E Iso ZS 315 4E Iso ZS 315 4E max Iso ZS 315 6E max Is...

Page 18: ...Iso ZS fan to AC power mains via a terminal box Wiring diagram for connection of Iso ZS fan to AC power mains via a power cable and a plug Terminal box Fan 220 240 V 50 Hz QF Automatic circuit breaker...

Page 19: ...19 QF 26 27 28 29 Iso ZS...

Page 20: ...premise at ambient temperatures from 10 C up to 40 C Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable...

Page 21: ...fan Seller Low air flow The ventilation system components as diffusers grilles air ducts are contaminated The fan components as the impeller or the spigot are contaminated The air ducts are damaged Th...

Page 22: ...l 22 The fan is recognized as serviceable Iso ZS 250 315 315 250 2 4E 6E GI G W1 max We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council D...

Page 23: ...Iso ZS 23 WARRANTY CARD...

Page 24: ...Iso ZS Iso ZS_v2 3 _EN...

Reviews: