Connection to the mains must be made through a disconnecting
device, which is integrated into the fixed wiring system in accordance
with the wiring rules for design of electrical units, and has a contact
separation in all poles that allows for full disconnection under
overvoltage category III conditions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in order
to avoid a safety hazard.
CAUTION: In order to avoid a safety hazard due to inadvertent
resetting of the thermal cut-out, this unit must not be supplied
through an external switching device, such as a timer, or connected
to a circuit that is regularly switched on and off by the utility.