•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE-FREE 

OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE 

UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE PURCHASE DATE STAMP.

Summary of Contents for Iso-Mix EC Series

Page 1: ...USER S MANUAL INLINE FANS IN SOUND INSULATED CASING EN Iso Mix EC ...

Page 2: ...7 Operation guidelines 8 Designation key 8 Installation and set up 9 Connection to power mains 13 Electronics operation algorithm 14 Technical maintenance 15 Troubleshooting 16 Storage and transportation regulations 16 Manufacturer s warranty 17 ...

Page 3: ... and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country READ THE USER S MANUAL CAREFULLY BEFORE PROCEEDING WITH INSTALLATION WORKS COMPLIANCE WITH THE MANUAL REQUIREMENTS ENSURES RELIABLE OPERATION AND LONG SERVICE LIFE OF THE UNIT KEEP THE...

Page 4: ...lation and maintenance The present user s manual should be carefully read before beginning works Single phase power mains must comply with the acting local electrical norms and standards Fixed electrical wiring must be equipped with an automatic circuit breaker The unit must be connected to power mains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between t...

Page 5: ...of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use ...

Page 6: ...put objects on it The unit is allowed to be used by children aged from 8 years old and above and persons with reduced physical sensory or mental capabilities or no experience and knowledge provided that they have been given supervision or instruction regarding safe use of the unit and understand the risks involved Do not allow children to play with the unit ...

Page 7: ...time The fan is designed for connection to ø 100 125 150 160 200 250 and 315 mm air ducts The fan is equipped with an energy efficient and high performance electronically commutated motor EC motor and a built in speed controller An external control unit can be connected to the fan The fan design is constantly being improved thus some models may be slightly different from those described in this ma...

Page 8: ...ins plug FR built in smooth speed controller and power cord with mains plug Rated spigot diameter mm Motor type Fan model OPERATION GUIDELINES The fan is rated for connection to single phase AC 230 V 50 60 power mains The fan is rated for continuous operation Air motion direction in the system must match the pointer on the fan casing Hazardous parts access and water ingress protection rating is IP...

Page 9: ...mounting on the floor on the wall or on the ceiling While mounting the fan provide extra protection against water ingress such as For the top mounting install an outer protecting hood above In case of any mounting position connect an air duct on both sides of the fan 4 x D 4 x D ...

Page 10: ...n turned off Mark the holes for fixing the fan and the power cable Lead the power cable to the ventilation hole drill the mounting holes and install the dowels Fix the fan with the screws For any mounting position connect an air duct on both sides of the fan ...

Page 11: ...an cover Installation locations of the R1 potentiometer XP1 and XP2 terminals are shown on the control board DIP switch SW Х1 Х2 R1 SW Connect the XP1 and XP2 terminal block counterparts Reassemble the fan in the reverse order Supply power to the fan S1 ...

Page 12: ...12 Features of different fan models control Iso Mix EC XXX G Iso Mix EC XXX GI Iso Mix EC XXX FR Thermostat control knob Speed control knob Speed control knob ...

Page 13: ...30 V 50 60 Hz power mains GND general Х2 terminal block for connection of an external speed controller TACH 2 signals per 1 revolution S1 external speed controller 0 10 V SW DIP switch QF external circuit breaker R1 internal speed controller N L QF 2 SW R1 X1 X2 blue red yellow blue white brown external control device 230 V 50 60 Hz DO NOT USE A METAL SCREWDRIVER KNIFE ETC FOR ADJUSTMENT OPERATION...

Page 14: ...XXX G Iso Mix EC XXX GI fans is equipped with an electronic module speed controller with an electronic thermostat for automatic motor speed control air flow depending on the air temperature The terminal compartment incorporates 2 control knobs motor speed preset button electric thermostat control knob The LED indicator is placed at the front panel of the fan to show the thermostat operating status...

Page 15: ... power supply and make sure electricity has been turned off Disconnect the air duct on both sides of the fan Clean the fan with a soft dry cloth or a brush Wipe the fan surfaces dry Connect an air duct on both sides of the fan Supply power to the fan CAUTION Do not allow water or liquid come into contact with electric components ...

Page 16: ...orted only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond t...

Page 17: ...air includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit f...

Page 18: ... unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the user s manual wi...

Page 19: ...19 Quality Inspector s Stamp Sold by name and stamp of the seller Manufacture Date Purchase Date ...

Page 20: ...blaubergventilatoren de B97 1EN 04 Iso Mix EC 100 125 150 G 160 GI 200 FR 250 315 ...