background image

27

Quality Inspector’s Stamp

Manufacture Date

Seller

(name and stamp of the seller)

Purchase Date

Summary of Contents for inWave

Page 1: ...User s manual inWave inWave EC INLINE MIXED FLOW FANS EN ...

Page 2: ...perating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the inWave EC unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace sa...

Page 3: ...hould be supervised to ensure that they do not play with the unit This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance sha...

Page 4: ...tions If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a safety hazard Ensure that the unit is switched off from the supply mains before removing the guard Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances Do not attach the product...

Page 5: ...quirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work permit for electrical units up to 1000V are allowed for in...

Page 6: ... contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The information in this user s manual was correct at the time of the...

Page 7: ...ouch the unit with wet or damp hands Never touch the unit when barefoot BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES READ THE RELEVANT USER MANUALS THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE ...

Page 8: ...t ø100 mm D D L L inWave EC 100 125 spigot ø125 mm D D D L L L inWave EC 150 spigot ø150 mm inWave EC 160 spigot ø150 mm with a rubber seal D D L L Ø D L B H M inWave EC 100 125 100 752 253 273 148 125 679 inWave EC 150 150 606 160 ...

Page 9: ... II devices Stream EC to class I Ingress protection rating against access to hazardous parts and water ingress is IPХ4 The fan is rated for operation at the ambient temperature ranging from 1 C up to 40 C DELIVERY SET Fan 1 pc Screws and dowels 4 pcs User s manual 1 pc Packing box 1 pc Rubber seal for the inWave 150 160 model 2 pcs BRIEF DESCRIPTION The product described herein is a mixed flow inl...

Page 10: ... sensor fixed on a 4 m cable Equipped with a power cord with a mains plug Timer based operation logic GS1 speed controller with an electronic thermostat and an outdoor temperature sensor fixed on a 4 m cable Equipped with a power cord with a mains plug Temperature based switching on off FR1 smooth speed controller from 0 to 100 and power cord with a mains plug W power cord with mains plug US speed...

Page 11: ...11 TECHNICAL DATA To comply with the ErP 2018 regulation a local demand controller and speed controller must be used ...

Page 12: ...NG The fan is suitable both for horizontal or vertical mounting on the floor on the wall or on the ceiling The fan can be installed independently or as part of a set with parallel or in series connection min 1 m ...

Page 13: ... model using the rubber seal On outlet discharge spigot side it is necessary to install in case of horizontal installation a duct with a length of at least 1 m in case of vertical installation a canopy preventing moisture from getting into the fan The outlet spigot must always be connected to the air duct 1 1 2 1 2 ...

Page 14: ...14 314 133 ...

Page 15: ... High Med Low L X N N High Med Low L X N N High Med Low L X N L ST QF QF QF QF N L LT N L ST QF N L LT L1 S N L ST QF N L LT L1 X X X High speed inWave inWave T Medium speed Low speed The fan wiring diagrams ...

Page 16: ... Med medium speed terminal Low minimum speed terminal QF automatic circuit breaker S external speed controller ST external switch for example a light switch X input terminal inWave EC L N L N X1 SW R1 R2 Designations on diagrams N neutral L line grounding R1 internal speed controller R2 external speed controller SW DIP switch ...

Page 17: ...17 inWave T 2 min 30 min inWave EC Х1 Х2 R1 SW ...

Page 18: ... ensure that there is no unusual noise or vibration at reduced motor speed When adjusting the voltage the motor current may exceed the rated current The fan is equipped with a thermal switch without self reset To reset the thermostat Switch off the power supply Find and eliminate the cause of overheating Check that the motor has cooled down to operating temperature Switch the power back on Thermos...

Page 19: ...r with an electronic thermostat for automatic speed control air flow depending on the air temperature The terminal compartment incorporates 2 control knobs presetting speed setting electric thermostat threshold value This indicator lights when the air temperature exceeds the set value To set the thermostat threshold rotate the thermostat control knob clockwise to increase or counter clockwise to d...

Page 20: ...d of the fan motor air flow in the range from minimum to maximum speed Rotations are controlled from minimum extreme right position to maximum extreme left position When rotating clockwise the rotations decrease DIP switch in EXT position The control signal is set by the S1 external control unit The inWave EC GT1 fan is equipped with an electronic module TSC speed controller with an electronic the...

Page 21: ...om dirt and dust Disconnect the fan from power mains prior to any maintenance operations To clean the fan use a soft cloth or a brush wetted in a mild detergent solution Do not allow water or liquid come into contact with electric components Wipe the surfaces dry after cleaning 1 2 1 1 2 ...

Page 22: ...e is connected correctly otherwise troubleshoot a connection error Internal connection fault Contact the Seller Low air flow The ventilation system is clogged Clean the ventilation system Increased noise vibration The impeller is clogged Clean the impeller The fan is not secured well or is not mounted properly Troubleshoot the installation error The ventilation system is clogged Clean the ventilat...

Page 23: ...hinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo Theunitcanbecarriedintheoriginalpackagingbyanymodeoftransportprovidedproperprotectionagainstprecipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during lo...

Page 24: ...air includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit f...

Page 25: ... unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the user s manual wi...

Page 26: ...26 ...

Page 27: ...27 Quality Inspector s Stamp Manufacture Date Seller name and stamp of the seller Purchase Date ...

Page 28: ...www blaubergventilatoren de B238EN 03 inWave________________________________ ...

Reviews: