MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. 
We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/
EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and 
of the Council and CE-marking Council Directive 93/68/EEC. This certificate is issued following test carried out on samples 
of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 60 months after the retail sale date provided the user's 
observance of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the 
course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user is entitled 
to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty 
repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the 
guaranteed period of operation. The faults are eliminated by means of replacement or repair of the unit components or a 
specific part of such unit component.

The warranty repair does not include: 

• 

routine technical maintenance

• 

unit installation/dismantling 

• 

unit setup

To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the 
payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact 
the Seller for warranty service. 

The manufacturer’s warranty does not apply to the following cases:

• 

User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission 
with missing component parts previously dismounted by the user.

• 

Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's 
manual.

• 

User’s failure to ensure timely technical maintenance of the unit.

• 

External damage to the unit casing (excluding external modifications as required for installation) and internal 

Summary of Contents for Cabrio Base 100

Page 1: ...USER S MANUAL Cabrio Base 100 AXIAL FAN EN...

Page 2: ...ions Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as co...

Page 3: ...ies or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensu...

Page 4: ...r full disconnection under overvoltage category III conditions Ensure that the unit is switched off from the supply mains before removing the guard All operations described in this manual must be perf...

Page 5: ...manual should be carefully read before beginning works Check the unit for any visible damage of the impeller the casing and the grille before starting installation The casing internals must be free of...

Page 6: ...order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The information in this user s manual was correct at the time of the document s preparation The Company reser...

Page 7: ...nt panel that opens when the fan is running and closes when the fan is not running which prevents backflow of air when the fan is off OPERATION GUIDELINES The fan is rated for connection to AC single...

Page 8: ...to power supply in compliance with the wiring diagram Fig 12 16 Step 6 Install the cover that closes the terminal block Fig 9 and the front panel on the fan casing Fig 10 Step 7 Provide power supply t...

Page 9: ...ts the interval timer operation for 12 hours rotation of the potentiometer clockwise in the rightmost position sets the interval timer operation for 24 hours to adjust the fan turn off delay time turn...

Page 10: ...closed ventilated premise with temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insul...

Page 11: ...he warranty repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by m...

Page 12: ...connection to power mains with a voltage different from the one stated in the user s manual Unit breakdown due to voltage surges in power mains Discretionary repair of the unit by the user Unit repair...

Page 13: ...13 EN 175 140 77 67 221 188 50 123 55 99 39 1 2...

Page 14: ...14 EN QF L N 3 4 5 6 7 8 9 10 11...

Page 15: ...n does not run Fan runs No Yes Switch S is OFF during countdown of the turn on delay timer Activation of the turn on delay timer for 60 seconds Activation of the interval timer 6 12 24 hours Activatio...

Page 16: ...e turn on delay timer Interval timer Fan does not run Activation of the turn off delay timer 2 30 minutes Fan runs with high speed No Yes Switch S is OFF during countdown of the turn on delay timer Ac...

Page 17: ...umidity is above set point Activation of the turn off delay timer 2 30 minutes S switch is ON Activation of the turn on delay timer for 60 seconds Switch S is OFF during countdown of the turn on delay...

Page 18: ...with low speed Humidity is above set point Activation of the turn off delay timer 2 30 minutes S switch is ON Activation of the turn on delay timer for 60 seconds Switch S is OFF during countdown of t...

Page 19: ...19 EN QF L N 17 18 19 20...

Page 20: ...20 EN...

Page 21: ...21 EN...

Page 22: ...22 EN...