8. Technical data 

 

 

 

BDC-66/dual voltage 

3x230 volt 

BDC-66 

3x400 volt 

Power consumption 

6,3 kW  IE3 

5,5 kW  IE3 

Electrical consumption 

3x 230 Volt IE3 

3x 400 Volt 

Frequency 

60 Hz 

50 Hz 

Amperage connection 

63 Ampere 

5 pole / 63 Ampere 

Supply cable 

4 x 16mm

(15m) 

4 x 16mm

2  

(15m) 

Available plug 

connections 

5 pole / 63 Ampere 

5 pole / 63 Ampere 

Air flow 

(with 20m hose 6” and 

medium shot blaster) 

1078m

3

/hr 

Air flow without hose 

2200m

3

/hr 

Vacuum 

51 mbar 

Dust hose connection 

Ø127mm / Ø150 mm 

Dust bin capacity 

150L 

Longo pack capacity 

25L 

Dust bag 

67,5L / 145L 

Length 

1731mm 

Width 

757mm 

Height 

1643mm 

Weight 

460kg 

 

Design and specifications are subject to change without notice by Blastrac B.V. 

 

 

 

Summary of Contents for BDC-66DBP

Page 1: ...OPERATING MANUAL BDC 66 VERSION 1 3...

Page 2: ...quirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 66 Serial number xxxx...

Page 3: ...afety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the ma...

Page 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 66 Medium risk for separating dust with an exposure limit value...

Page 5: ...act plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be...

Page 6: ...e hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassemb...

Page 7: ...connection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the elect...

Page 8: ...compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the contents of the dust bin Regular open the dra...

Page 9: ...uninterrupted operation When the indicated number of working hours is not achieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once...

Page 10: ...the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in th...

Page 11: ...k by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the und...

Page 12: ...cable 4 x 16mm2 15m 4 x 16mm2 15m Available plug connections 5 pole 63 Ampere 5 pole 63 Ampere Air flow with 20m hose 6 and medium shot blaster 1078m3 hr Air flow without hose 2200m3 hr Vacuum 51 mba...

Page 13: ...gton Sheffield South Yorkshire GB S25 3QY England Tel 0044 1909 56 91 18 Fax 0044 1909 56 75 70 Info blastrac co uk Blastrac Germany Richard Byrd Stra e 15 D 50829 K ln Ossendorf Tel 0049 221 70 90 32...

Reviews: