background image

 

 

11 

 

 
 
Advised is to take contact with Blastrac Support in order to prevent operational problems. 
 
 
Compressor 

 

Replacement or cleaning of the air filter of the compressor (item 11 page 5) is depending on the environment 
in which the Dust collector is operating.   
 

 

Advised is to take contact with Blastrac support in order to prevent operational problems. 
 

7. Technical data 

 
 

 

BDC-454  

3x230 volt 

BDC-454 

3x400 volt 

Power consumption 

6,3 kW  IE3 

5,5 kW  IE3 

Electrical consumption 

3x 230 Volt IE3 

3x 400 Volt 

Frequency 

60 Hz 

50 Hz 

Amperage connection 

32 Ampere 

5 pole / 32 Ampere 

Supply cable 

4 x 16mm

(15m) 

4 x 6mm

2  

(15m) 

Available plug 

connections 

5 pole / 32 Ampere 

5 pole / 32 Ampere 

Air stream 

(hose 5” at the end) 

900 m3/hr 

Dust hose connection 

Ø75 / 2xØ75 / Ø100

 / Ø127 mm 

Dust bin capacity 

100 L 

Longo pack capacity 

15 L 

Small bag 

67.5 L 

Length 

1344 mm 

Width 

665 mm 

Height 

1428 mm 

Weight 

267 kg 

 

Design and specifications are subject to change without notice by Blastrac B.V. 

 

Summary of Contents for BDC-454

Page 1: ...OPERATING MANUAL BDC 454 VERSION 2 2...

Page 2: ...ty requirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 454 Serial numbe...

Page 3: ...general Safety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work w...

Page 4: ...ndard EN 60335 2 69 Annexe AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 454 Medium risk for separating dust w...

Page 5: ...ssor ON OFF 4 Rubber impact plate 10 Drain valve Open regular to remove water from the air tank 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar...

Page 6: ...dust from escaping Always close the inlet of the dust collector with the appropriate plug Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust c...

Page 7: ...n earthed connection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test...

Page 8: ...hine Connect the dust collector to the power supply Switch on the main switch Switch on first the compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop...

Page 9: ...uninterrupted operation When the indicated number of working hours is not achieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once...

Page 10: ...zed air built up by a compressor The air is leaded through a water separator to the pulse system The cooled air passes a control valve which regulates the systems pressure and then builds up pressure...

Page 11: ...30 volt BDC 454 3x400 volt Power consumption 6 3 kW IE3 5 5 kW IE3 Electrical consumption 3x 230 Volt IE3 3x 400 Volt Frequency 60 Hz 50 Hz Amperage connection 32 Ampere 5 pole 32 Ampere Supply cable...

Page 12: ...gton Sheffield South Yorkshire GB S25 3QY England Tel 0044 1909 56 91 18 Fax 0044 1909 56 75 70 Info blastrac co uk Blastrac Germany Richard Byrd Stra e 15 D 50829 K ln Ossendorf Tel 0049 221 70 90 32...

Reviews: