www.blastrac.com ‒ info@blastrac.
com
Instruction manual BDC-24-230V-P
8/16
I
US
Primary cartridge filters operation
Figure 6
1.
Electropneumatic device
2.
Filter cartridges
3.
Timer
The filtering cartridges (
2
) serve the purpose of filtering
the intake air. The vacuum cleaner is equipped with a fully
automatic electropneumatic device (
1
) to alternately clean
the filtering cartridges (
2
) which guarantees continuous
service; powered with a 24V rating, is complete with cyclic
timer (
3
) to regulate the following times:
T3
= time between one cleaning cycle and the next, set on 0
seconds;
T2
= time between one cleaning operation of the cartridge
(
2
) and the next, set on 20 seconds;
T1
= opening time of the solenoid valve for backwashed air
exhaust into the cartridge, set at 1 tenths of a second.
The shorter the time, the more energetic the cleaning
action will be.
Factory setting should not be changed if without
consulting Blastrac.
The three solenoid valves of the electropneumatic device
control the cleaning of the relative filter cartridges.
Figure 6A
1.
Filter cleaning solenoid valve E1
2.
Filter cleaning solenoid valve E2
3.
Filter cleaning solenoid valve E3
Emergency stopping
Press Stop button (
5
- Fig. 4). The vacuum cleaner stops.
WARNING!
The motors and internal components of the vacuum
cleaner will still be electrically powered.
To start the vacuum cleaner, see the starting and stopping
paragraph
Emptying the dust container
WARNING!
■
Before proceeding with these operations, turn
the vacuum cleaner off and disconnect the plug
from the power socket.
■
Check the class of the vacuum cleaner.
■
Version not suitable for vacuuming hazardous dust
▪
Release dust container (
1
- Fig. 7), with lever (
2
),
then remove and empty it.
▪
Make sure the seal is in perfect condition and
correctly positioned.
▪
Place the container back in position and secure it
again.
Vacuum cleaner operation
WARNING!
The air speed in the suction tube must not be less
than 20 m/s.
This state is shown by the green indicator of the
primary filter.
When using the vacuum cleaner, check:
■
The state of the max. vacuumed material level indicator
(
6
- Fig. 4) if the level check is installed.
■
The state of the primary filter (
8
- Fig. 4) and the
absolute filter (if installed) (
9
- Fig. 4).
WARNING!
If one of the indicators is lit, follow the instructions.
Symbol
Indicator
signal
Indicator
colour
Vacuum cleaner
state and
procedure
bar/psi
MAX
Max. vacuumed
material level
(6 - Fig. 4)
Red
Suction stopped.
Empty the container
(see relevant
paragraph).
bar/psi
MAX
Primary filter
(8 - Fig. 4)
Red
Suction on.
Replace the cartridge
filters.
(see relevant
paragraph).
bar/psi
MAX
Absolute filter
(9 - Fig. 4)
Red
Suction on.
Change absolute filter
(see relevant
paragraph).
WARNING!
Consult the “Troubleshooting” chapter if faults
occur.
Summary of Contents for BDC-24-230V-P
Page 2: ......
Page 53: ...www blastrac com info blastrac com Instruction manual BDC 24 230V P 3 8 5 8 1 5 6 3 7 2 4...
Page 54: ...www blastrac com info blastrac com Instruction manual BDC 24 230V P 4 8 6A 6 1 2 3 3 1 2...
Page 55: ...www blastrac com info blastrac com Instruction manual BDC 24 230V P 5 8 7 8 8A 1 2 2 1 3...
Page 57: ...www blastrac com info blastrac com Instruction manual BDC 24 230V P 7 8 12 13 1 2 1 2 3 4...
Page 65: ......