GB
Instruction Manual BDC-122M / BDC-122H
www.blastrac.eu ‒ [email protected]
10/18
Controls and indicators
Figure 5
1.
Main motor Start/Stop indicator and button
You can start/stop the main motor with this
button. If the indicator is lit, the main motor is
ON.
2.
Second motor Start/Stop indicator and
button
You can start/stop the second motor with this
button. If the indicator is lit, the second motor is
ON.
3.
Vacuum gauge
4.
Manual filter shaker lever
Inspections prior to starting
Figure 6
1.
Inlet
Before starting, check that:
■
The filters are installed;
■
The closing band is properly tightened;
■
The vacuum hose and tools have been correctly
fitted into the inlet (
1
);
■
The Longopac
®
bag (
2
, Fig.
1
) is installed.
WARNING!
Lock the castor brakes before starting the
vacuum cleaner (2, Fig. 6).
WARNING!
Do not use the device if the filters are faulty.
Starting and stopping the vacuum
cleaner
Figure 5
■
Turn the button (
1
) to “I” position to start the
first motor (indicator light on).
■
Turn the button (
2
) to “I” position to start the
second motor (indicator light on).
■
Turn the button (
1
) to “0” position to stop the
first motor (indicator light off).
■
Turn the button (
2
) to “0” position to stop the
second motor (indicator light off).
Operation
Figure 7
Vacuum gauge (
2
): green zone (
3
), red zone (
1
)
When using the vacuum cleaner:, check the flow
control:
■
when the vacuum cleaner is operating, the
pointer of the vacuum gauge must remain in the
green zone (
3
) to ensure that the speed of the
intake air does not drop below the safety value of
20 m/sec;
■
If the pointer is in the red zone (
1
) it means that
the speed of the air in the vacuum hose is less
than 20 m/s, and that the vacuum cleaner is not
operating in optimal conditions. Shake or replace
the filter.
■
during normal operation conditions, close the
vacuum hose, the pointer of the vacuum gauge
must switch from the green zone (
3
) to the red
zone (
1
).
WARNING!
When the vacuum cleaner is operating,
always check that the vacuum gauge pointer
remains in the green zone (3).
Consult the “Troubleshooting” chapter if
faults occur.
WARNING!
The air speed in the suction tube must not be
less than 20 m/s.
Condition indicated by the vacuum gauge
pointer in the green zone (3).
WARNING!
All vacuum cleaners can be used only with
hoses whose diameters comply with the
specifications in the “Technical Data” table.
WARNING!
Consult the “Troubleshooting” chapter if
faults occur.
Summary of Contents for BDC-122H
Page 19: ...GB Instruction Manual BDC 122M BDC 122H www blastrac eu info blastrac eu 18 18...
Page 21: ...www blastrac eu info blastrac eu 2 16 Operating manual BDC 122M BDC 122H 3 A B C 4 C A B...
Page 22: ...www blastrac eu info blastrac eu 3 16 Operating manual BDC 122M BDC 122H 6 1 1 2 5 1 4 2 3...
Page 29: ...www blastrac eu info blastrac eu 10 16 Operating manual BDC 122M BDC 122H 11 1 2 3...
Page 30: ...www blastrac eu info blastrac eu 11 16 Operating manual BDC 122M BDC 122H 11 5 4 12 2 1...
Page 31: ...www blastrac eu info blastrac eu 12 16 Operating manual BDC 122M BDC 122H 13 14 1 2...
Page 32: ...www blastrac eu info blastrac eu 13 16 Operating manual BDC 122M BDC 122H 15 Model EU...
Page 33: ...www blastrac eu info blastrac eu 14 16 Operating manual BDC 122M BDC 122H 16 Model US...
Page 35: ...www blastrac eu info blastrac eu 16 16 Operating manual BDC 122M BDC 122H...
Page 36: ......
Page 37: ......
Page 38: ......