![Blastrac 1-15 Global Operating Manual Download Page 7](http://html1.mh-extra.com/html/blastrac/1-15-global/1-15-global_operating-manual_2769731007.webp)
7
Operating manual 1-15DS Global
7/12
4. Initial operation
Before using the machine it is of great importance to inspect the machine.
It is not permitted to use the machine if the machine safety is not according the
checkpoints below.
Checkpoints power supply
Use only extension cables for extending the main cable that are sized and marked
in accordance with the overall power consumption of the machine.
Electrical cables must be fully unwind of them reels.
No damage is permitted for electrical cables.
Use a electrical power supply connection with earth connecting.
Checkpoints of machine
Safety functions and operating functions must work correct.
Check the following parts for damage and wear: blastwheel, feedspout, liners,
magnet- and brush sealing.
No loose bolts and nuts permitted
No any damage of electrical components permitted.
Dust hose must be undamaged and the connection must be reliable.
Check de parts of the separator on wear and defects. Remove foreign bodies and
dust deposits.