OPERATION
The SnakeBite XQ Nozzle and Silencer are
designed to operate effectively across a
wide range of operating pressures, typically
between 80-110psi, with the optimal and
recommended operating pressure being
100psi. Operating the nozzle and silencer
at pressures other than the recommended
pressure will reduce cleaning efficiency and
silencing effect.
It is recommended the blast system used is a
BlastOne Schmidt Pressure hold system fitted
with a 2” bull hose coupled to an adequately
sized compressor for the nozzle size used – see
BlastOne catalogue for compressor sizing.
The SnakeBite XQ has been designed to optimise
abrasive blasting using GMA Australian Garnet.
Use with alternative abrasive types may result
in reduced performance outcomes compared to
using GMA Australian Garnet.
Preparing to use the nozzle and silencer
1. Setup Blast system in accordance with
manufacturers instructions and connect
nozzle and silencer as per instruction
above.
2. Clear the work area of any debris and
trip hazards and observe all safety
requirements.
3. Pressurise the system and set the nozzle
outlet pressure to 100psi.
Operator standoff
1. The improved blast stream stability
generated by the SnakeBite XQ Nozzle will
allow an increased standoff distance and
faster cleaning rates - around 500-600mm
(20-24 in) for typical situations.