6
HCB x00
Part N
o
: 965x.01
Headend Controller
Headend control unit with 8A power supply
B
LINE
10. Programming
10.1 Main program
*
only available for HCB 200
10.2 Adjustments
BLANKOM
ENTER
Selection modules
IP number
Type/ article number
Change module
(
)
see operating instructions of the module
Change configration
Change IP number
System restart
NIT distribute
Temperature
Voltage
Contrast
Version
Back
Reset
Configuration
Address selection
display
distribute static NIT
display
temperature
display
voltage
+/-
display/ selection
display
version
abort
any
key
any
key
any
key
OK
any
key
Current *
display
current
any
key
1.1
1
2.1
2
System restart
Time
Language
starting time
display/ selection
hours/ minutes
display/ selection
display/ selection
german/ english
Manuel adjustment
•
Adjustment of the addresses at the Bus Extender BEB x00
and at the modules
•
Activation of the data input at the Headend Controller HCB
x00 by pressing the “ENTER”-key
•
Display/ adjustment of the parameter of the HCB x00 or a
selected module as in chapter 11.1
•
Activation of the programming modus of each module by
selecting the line (BEB x00) and the module position (01 …
15) at the Headend Controller (HCB x00)
→
the yellow LED
at the module will be lit up til the beginning of the parameter
adjustment
•
Adjustment of the parameter at the selected module accor-
ding to the individual product description
•
After the programming the data will be transmitted automa-
tically to the modules
→
the yellow LED on the HCB x00 will
be lit up during the data transfer process
•
The green LED shows the operating status
Adjustment with the PC/ laptop
•
An “online connection” after IP-standard and an ethernet
connection at the PC/ laptop is necessary for the remote
programming
•
Adjustment of the line/ position addresses at the Bus Exten-
der BEB x00 as well as at the modules
•
At the HCB x00 IP-address input (e.g. 192.168.001.001)
•
For “direct connection” between a PC and HCB x00 use a
crossed patch cable (RJ 45)
•
For connection over a deviation use an uncrossed patch
cable
•
HTML-browser start-up and IP-address as target address
input
•
If connected correctly the HTML control surface at the PC
will open up and a blue LED (LINK) at the HCB x00 will be
lit up
•
All adjustments of the modules are specified at the control
surface
Adjustment of removal of write protection
•
Removal of write protection by input of “0000” (password)
and “0000” (user)
Default IP Address
•
192.168.2.80
see chapter 11.3
see chapter 11.4
ENTER
Going back
Going forward