Blankom 9652.01 Operating Instructions Manual Download Page 6

6

HCB x00

Part N

o

: 965x.01

Headend Controller

Headend control unit with 8A power supply

B

LINE

10. Programming

10.1 Main program

 

 

 

 

 

 

 

 

 

 

                 

only available for HCB 200

10.2 Adjustments

BLANKOM

ENTER

Selection modules

IP number

Type/ article number

Change module

(

)

see operating instructions of the module

Change configration

Change IP number

System restart

NIT distribute

Temperature

Voltage

Contrast

Version

Back

Reset

Configuration

Address selection

display

distribute static NIT

display

temperature

display

voltage

+/-

display/ selection

display

version

abort

any
key

any
key

any
key

OK

any
key

Current *

display

current

any
key

1.1

1

2.1

2

System restart

Time

Language

starting time

display/ selection

hours/ minutes

display/ selection

display/ selection

german/ english

Manuel adjustment

• 

Adjustment of the addresses at the Bus Extender BEB x00 
and at the modules

• 

Activation of the data input at the Headend Controller HCB 
x00 by pressing the “ENTER”-key

• 

Display/ adjustment of the parameter of the HCB x00 or a 
selected module as in chapter 11.1

• 

Activation of the programming modus of each module by 
selecting the line (BEB x00) and the module position (01 … 
15) at the Headend Controller (HCB x00) 

 the yellow LED 

at the module will be lit up til the beginning of the parameter 
adjustment

• 

Adjustment of the parameter at the selected module accor-
ding to the individual product description

• 

After the programming the data will be transmitted automa-
tically to the modules 

 the yellow LED on the HCB x00 will 

be lit up during the data transfer process

• 

The green LED shows the operating status

Adjustment with the PC/ laptop

• 

An “online connection” after IP-standard and an ethernet 
connection at the PC/ laptop is necessary for the remote 
programming

• 

Adjustment of the line/ position addresses at the Bus Exten-
der BEB x00 as well as at the modules

• 

At the HCB x00 IP-address input (e.g. 192.168.001.001)

• 

For “direct connection” between a PC and HCB x00 use a 
crossed patch cable (RJ 45)

• 

For connection over a deviation use an uncrossed patch 
cable

• 

HTML-browser start-up and IP-address as target address 
input

• 

If connected correctly the HTML control surface at the PC 
will open up and a blue LED (LINK) at the HCB x00 will be 
lit up

• 

All adjustments of the modules are specified at the control 
surface

Adjustment of removal of write protection

• 

Removal of write protection by input of “0000” (password) 
and “0000” (user)

Default IP Address

• 

192.168.2.80

see chapter 11.3

see chapter 11.4

ENTER
Going back

Going forward

Summary of Contents for 9652.01

Page 1: ...uration without Bus Extender 3 6 2 Standard configuration with Bus Extender 4 7 Head end bus structure 4 8 Redundancy circuit 4 9 Alarm function 5 10 Technical data 5 11 Programming 6 10 1 Main progra...

Page 2: ...he DIN EN 50083 have to be considered Especially the safetyrelevant execution of the DIN EN 60728 11 1 is necessary 2 Device variants HCB 200 9652 01 Headend control unit with 8A power supply 100 240...

Page 3: ...matically to the respective line The Headend Controller HCB 200 has an integrated current display but the HCB 300 hasn t this function It is recom mended to use an individual control unit for every ci...

Page 4: ...y if the Bus Extender BEB x00 is failing HCB x00 Headend Controller BEB x00 Bus Extender Module signal processing unit HCB x00 Module ADDR 15 BEB x00 ADDR 01 BEB x00 ADDR 02 BEB x00 ADDR 15 Module ADD...

Page 5: ...IEC 320 C8 3 Power consumption max 110 W Output DC voltage 12 V Rippled noise ratio 66 dB Current drain max 8 A Current limit yes 9 A typical Short circuit protection yes Overvoltage protection yes 14...

Page 6: ...15 at the Headend Controller HCB x00 the yellow LED at the module will be lit up til the beginning of the parameter adjustment Adjustment of the parameter at the selected module accor ding to the indi...

Page 7: ...rect input or selection all characters numbers capital letters only 1 1 1 1 IP number webserver xx or zz see fig right Subnet mask Gateway address DHCP address Trap address VEA EMA IP number 21 Softwa...

Page 8: ...87 6 EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement IEC CISPR 22 2005 modified A1 2005 German version EN 55022 2006 A1 2007 7 EN 61000 4...

Page 9: ...basic document H u er Rudolph 1 01 30 07 2009 revision H u er 1 02 15 12 2009 revision program flow H u er 1 03 11 01 2010 insert of HCB 300 H u er BLANKOM Antennentechnik GmbH Hermann Petersilge Stra...

Page 10: ...he conformity of the products Product name Headend Controller Type HCB 200 HCB 300 Product number 9652 01 9653 01 according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and a...

Reviews: